  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 2631-2634 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new detection scheme for Fourier transform-ion cyclotron resonance (FT-ICR) studies is proposed and initial experimental results are presented. While in conventional FT-ICR, the difference of the transient signals from two opposite electrodes is recorded and Fourier transformed, it is also possible to use the sum of these signals. In this way resonances are observed at the harmonic of the reduced cyclotron frequency 2 ν+ as well as ν+−ν− and ν++ν−, the later being important for accurate mass measurements. The experiments were performed with a Penning trap in an electromagnet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0630
    Keywords: 07.65.Eh ; 32.70.Fw ; 32.80.Dz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Resonance ionization mass spectroscopy (RIMS) and pulsed-laser induced desorption (PLID) have been combined for ultrasensitive detection and spectroscopy of very small samples of refractive elements. The method has been tested and applied to laser spectroscopy of 5×109 atoms (1.5 pg) of195Au (T 1/2= 183d) implanted at the ISOLDE online mass separator with 60 keV into graphite. A pulsed thermal atomic beam was formed by laser desorption with a 10 ns Nd∶Yag laser pulse. Subsequently the atoms were photoionized in a three-colour, three-step resonant excitation to an autoionizing state. The selectivity was enhanced by a time-of-flight measurement of the photo ions. In resonance, one ion was detected per 105 atoms implanted resulting in a gain in detection efficiency by three orders of magnitude in comparison to the use of a continuous atomic beam. In the course of the experiments several unknown autoionizing states were found, and the lifetime of the 6d 2 D 3/2 state of gold was determined to beτ=10.7(6) ns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Resonance ionization mass spectroscopy (RIMS) and pulsed-laser induced desorption (PLID) have been combined in order to study the isotope shift (IS) and hyperfine structure (HFS) of184Au (T1/2=53 s) and183Au (T1/2=42 s) in the 6s2S1/2 → 6p2P1/2 (λ=267 nm) transition. The Au isotopes were obtained as daughters in the decay of184,183Hg produced and mass separated at the new ISOLDE-3 facility at CERN. It was found that the strong deformationβ 2}-0.25 setting in at186Au persists down to183Au.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 332 (1989), S. 107-108 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The changes of the mean-square charge radii have been measured for198Pt-183Pt by means of resonance ionization mass spectroscopy (RIMS) at the new on-line isotope separator ISOLDE-3/CERN. As in the case of the neighbouring isotopes of Au and Hg, a strong nuclear deformation of ¦β2¦ −-0.24 is reached at the neutron mid-shell nucleus183Pt, but no indication for a sharp shape transition is observed from the study of the isotope shifts.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 321 (1985), S. 537-547 
    ISSN: 1434-601X
    Keywords: 21.10.-k ; 27.80+w ; 31.30.Gs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The isotope shift between197Au (stable) and the radioactive Au isotopes190Au,191Au,192Au and193Au were determined by resonance fluorescence spectroscopy in the 6s 2 S 1/2–6p 2 P 1/2.λ=267.6nm line. The unstable Au isotopes were produced at the ISOLDE mass separator at CERN. The nuclei were investigated semi on-line in a resonance vessel, heated to 1,400°C. The results areδν 190,197=−11.12(39) GHz,δν 191,197=−9.67(12) GHz,δν 192,197=−8.32(15) GHz,δν 193,197=−6.29(11) GHz, corresponding to a change of the mean-square charge radius byδ〈r 2〉190,197 =0.261(12) fm2,δ〈r 2〉191,197=0.227(5) fm2,δ〈r 2〉192,197=0.195(5) fm2,δ〈r 2〉193,197 =0.148(4) fm2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0649
    Keywords: 32 ; 42.60 ; 07.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Laser photoionization has been used to detect trace amounts of plutonium. A high sensitivity and selectivity has been achieved by applying three-step excitation and ionization of the plutonium atoms with high pulse-repetition rates and additional mass determination by time-of-flight measurements. A laser system was developed which consists of a copper vapor laser pumping three dye lasers simultaneously. Samples containing between 1010 and 1012 atoms of239Pu on Re filaments were measured yielding strong resonance signals with maximum ion count rates of several kHz at a vanishingly low background. A detection efficiency of 10−7 was determined allowing the detection of about 108 plutonium atoms in a sample.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 38 (1985), S. 65-70 
    ISSN: 1432-0649
    Keywords: 42.80 ; 32.80F ; 32.80H
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Resonance ionization mass spectrometry (RIMS) has been tested for the isotope-selective determination of trace amounts of plutonium. An atomic beam is formed by evaporating plutonium atoms from a rhenium-filament heated to 1800 °C. The radiation of a pulsed dye laser excites the atoms in a two-photon process (λ=595.2 nm) followed by photoionization of the excited atoms. Mass selectivity is obtained by use of a time-of-flight spectrometer. A resonant signal of239Pu was measured with 1013 atoms deposited on the filament.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Hyperfine interactions 24 (1985), S. 69-93 
    ISSN: 1572-9540
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Hyperfine structure and isotope shift of radioactive Hg, Au and Cd isotopes have been determined by optical spectroscopy. In all cases the atoms were confined in a resonance cell. The various variants of the cell technique and alternative methods as the resonance ionization spectroscopy related to the investigation of short-lived nuclei are described, and some results are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 331 (1988), S. 133-135 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A laser ion source has been set up which is based on resonant stepwise excitation and ionization of atomic vapor confined in an ionization chamber. Using a pulsed copper vapor/dye laser system with a high repetition rate (6.5 kHz) one expects high efficiency and high selectivity for this new type of ion source. First test experiments with lead are reported.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A resonant ionization mass spectrometer has been developed as an analytical tool for the detection of trace elements, especially of plutonium and other radionuclides. The sample, deposited on a rhenium filament, is evaporated by electrical heating and the atoms of the element under investigation are selectively ionized by laser light delivered from three dye lasers pumped by a copper vapour laser. The resulting photoions are detected in a time-of-flight spectrometer with a channelplate detector. For plutonium a mass resolution of M/δM=1500 was obtained and an overall detection efficiency of 4×10−6 was determined for stepwise excitation and ionization via autoionizing states. With a laser light bandwidth of 3–5 GHz neighbouring isotopes could be suppressed by a factor of 20 due to isotope shifts in the excitation transitions. The isotope composition of synthetic samples was measured and good agreement was found with mass spectroscopic results. The influence of the hyperfine structure on the isotope ratios is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...