Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (3)
  • 1975-1979  (4)
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 103 (1981), S. 5327-5333 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 103 (1981), S. 6988-6989 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 41 (1976), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Protein concentrations in milk were compared using a modified Lowry and the micro-Kjeldahl methods. Correlation coefficients for absorbance (Lowry) vs protein (Kjeldahl) were 0.925, 0.904 and 0.899 for individual Holstein, individual Guernsey and bulk raw milk samples, respectively, whereas, the R2 was 0.9998 for samples of 2.5-4.0% protein prepared from three brands of nonfat dry milk. Added lactose, up to 16 mg/ml milk, did not interfere in the test. Storage at 4°C for up to 6 days was without effect. However, whey proteins had a lower specific absorbance than did casein. The standard deviation of differences among triplicate Lowry tests was about one-third of that for duplicate micro-Kjeldahl tests.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 15 (1978), S. 65-71 
    ISSN: 1432-0630
    Keywords: 78.70
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The effects of uncertainties and errors in various constraints used in the analysis of multi-component life-time spectra of positrons annihilating in metals containing defects have been investigated in detail using computer simulated decay spectra and subsequent analysis. It is found that the errors in the fitted values of the main components lifetimes and intensities introduced from incorrect values of the instrumental resolution function and of the source-surface components can easily exceed the statistical uncertainties. The effect of an incorrect resolution function may be reduced by excluding the peak regions of the spectra from the analysis. The influence of using incorrect source-surface components in the analysis may on the other hand be reduced by including the peak regions of the spectra. A main conclusion of the work is that extreme caution should be exercised to avoid introducing large errors through the constraints used in the analysis of experimental lifetime data.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 359-365 
    ISSN: 1432-1041
    Keywords: chlorpheniramine ; pharmacokinetics ; oral absorption ; half-life ; bioavailability ; volume of distribution
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Plasma and urinary levels of chlorpheniramine (CPM) and its 2 demethylated metabolites were measured by HPLC after i.v. and oral dosing. In 5 mg (maleate) i.v. bolus studies in 2 subjects, plasma CPM levels were fitted to triexponential equations with terminal half-lives (t 1/2) of 23 and 22 h and area of 3.6 and 3.21/kg, respectively. Intravenous data predicted hepatic blood extraction ratios for the 2 subjects to be 0.06 and 0.07, respectively. Absolute bioavailability from oral solution (10 mg) was 59 and 34%, and from tablets (8 mg) 44 and 25%, respectively, indicating extensive gut first-pass metabolism. Mean t 1/2 from 7 oral fasting studies in 5 subjects was 28 h (19–43 h). Mean absorption lag time was 0.7 h (0.4–1.3 h), and mean peak time was 2.8 h (2–4 h). In 2 subjects, 6 mg solutions were given every 12 h for 9 doses; good correlation between single and multiple dose kinetics was found. Significant accumulation was demonstrated in simulation studies with frequent daily dosing. Estimated accumulation ratios vary from 4.1 to 9.4 (mean 6.5). The t 1/2 from urinary data (collected for 12 days) was consistent with plasma data. The above results suggest the need to reexamine the current practice of frequent daily dosing and the use of sustained or controlled release dosage forms of this drug. The possible cause of reduced plasma clearance of CPM in renal patients is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 23 (1977), S. 701-714 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A recent design procedure for perforated plate extraction columns requires extension to include jetting conditions at each perforation. For this purpose, correlations are obtained for jet length, jet contraction, drop size, and mass transfer coefficients in disperse phase controlled liquid-liquid systems. Experimental variables include nozzle size, flow velocity, and physical properties.
    Additional Material: 21 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 80-87 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This study enables the extension of a recent design procedure for perforated plate extraction columns to include operation under jetting conditions. Correlations of experimental data are given for jet length, jet contraction, drop size, and mass transfer rates in continuous phase controlled liquid-liquid systems. Systems exhibiting very low mass transfer rates were used, and this gave significantly different results from those obtained earlier with moderate rates of mass transfer.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...