Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 21 (1983), S. 688-696 
    ISSN: 1741-0444
    Keywords: Artificial lung ; Gas transfer ; Membrane oxygenator ; Oxygenator ; Reciprocating motion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A method of increasing the rate of oxygen transfer into the liquid in a membrane oxygenator was investigated. A reciprocating motion was imparted to a microporous membrane separating a deoxygenated saline solution from air, and the concentration of dissolved oxygen was measured. Rates of oxygen transfer were calculated for a smooth membrane surface in contact with the liquid, for a screen-roughened surface, and for a roughened surface with additional turbulence promoters attached. The mass transfer coefficients obtained from these experiments are in the upper range of literature values for membrane oxygenators. The screen roughness increased the transfer rates by a factor of approximately three compared with the smooth surface. The turbulence promoters had no further effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...