    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 18 (1980), S. 65-69 
    ISSN: 1741-0444
    Keywords: Electrocutaneous stimulation ; Myoelectric control ; Prosthetics ; Sensory feedback
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Progress in the development of a system to provide sensory feedback of the pinch force of an artificial hand is described. Design criteria relating to electrocutaneous stimulation and compatibility with myoelectric control are discussed. Details of a practical system, presently in use by two amputees prior to full-scale clinical evaluation, are presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 21 (1983), S. 688-696 
    ISSN: 1741-0444
    Keywords: Artificial lung ; Gas transfer ; Membrane oxygenator ; Oxygenator ; Reciprocating motion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A method of increasing the rate of oxygen transfer into the liquid in a membrane oxygenator was investigated. A reciprocating motion was imparted to a microporous membrane separating a deoxygenated saline solution from air, and the concentration of dissolved oxygen was measured. Rates of oxygen transfer were calculated for a smooth membrane surface in contact with the liquid, for a screen-roughened surface, and for a roughened surface with additional turbulence promoters attached. The mass transfer coefficients obtained from these experiments are in the upper range of literature values for membrane oxygenators. The screen roughness increased the transfer rates by a factor of approximately three compared with the smooth surface. The turbulence promoters had no further effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 18 (1980), S. 287-290 
    ISSN: 1741-0444
    Keywords: Man-machine systems ; Multistate control ; Myoelectric control ; Prosthetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A myoelectric control system is one in which the operation of a device is controlled by the electric potential produced by voluntary contraction of a muscle. The utilisation of a single muscle site for the 3-state control of a myoelectric prosthesis has proven beneficial for certain amputees. It has been proposed that a single muscle site could be used for 5-state control, perhaps for an elbow and hand. This paper presents a preliminary study of the error probability for 5-state control.
    Type of Medium: Electronic Resource