Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 11-15 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; ECD ; Halocarbons in water, 0.1-10 ppb ; 0.5-2 μl injected on-column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Interest in monitoring halogenated organics in drinking water and natural surface and ground water in the low ppb range continues to grow. There is a tendency to include still more volatile halocarbons, the trace determination of which is known to be rather demanding. This prompted us to re-examine the feasibility of large-volume direct aqueous injection onto capillary columns, coupled with ECD. A primary problem was to avoid simultaneous elution of water with halocarbons, since water suppresses the ground current of the ECD. The following measures contributed to the solution of this problem.Apolar, extremely inert, columns are required to elute water completely, and even before very light halocarbons. Their coatings have to be far thicker (≍ 5 mUm) than commonly employed thick films since they must permit isothermal analysis at a column temperature around 100°C in order to ensure rapid and complete elution of water. Finally, it is essential that sampling be carried out on-column for two reasons: diffusion of water vapor in the injector, resulting in delayed elution, is then eliminated, and peak distortion during splitless injection is avoided.Although we now know that persilylated columns with immobilized coatings withstand routine water injections, more longterm experience is needed to provide detailed recommendations for the handling of these columns.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 34-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Samples with varying water content ; Retention times correlated with water content ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 340-342 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Sample preparation ; Closed loop stripping analysis ; Charcoal adsorbent filter ; Overcoming contamination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 492-494 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Closed loop stripping analysis ; Filter extraction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für die chemische Industrie 77 (1965), S. 461-462 
    ISSN: 0044-8249
    Keywords: Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Helvetica Chimica Acta 52 (1969), S. 335-361 
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The possible transition state conformations (chair (S), boat (W), and twist (T), respectively cross (K) forms) and methods for their determination in the thermal ortho-CLAISEN rearrangement of allyl aryl ethers are discussed.Crotyl 3,5-dimethylphenyl ether (11) gives a mixture of 2-(α-methylallyl)-3,5-dimethyl-phenol (12) and 4-crotyl-3,5-dimethyl-phenol (13) on heating in N, N-diethylaniline. Values of 3 and 31 were obtained for the ratio of 12/13 for trans-11 and cis-11, respectively. It therefore follows that both ethers rearrange steroselectively ( 〉 90%) by the S or W forms of the activated complex.αMethylallyl 6-alkylphenyl ethers rearrange on heating in various solvents to a mixture of trans-and cis-2-crotyl-6-alkyl-phenols. The amount of the cis-phenols in the rearrangement products decreases with the increasing bulk of the 6-alkyl substituent. This result is only obvious if the chair form of the transition state during the rearrangement of these ethers is highly favoured.trans-Crotyl 2,6-dimethylphenyl ether (trans-33) rearranges highly steroselectively (94%) on heating to trans-4-crotyl-2,6-dimethyl-phenol (trans-34). In the case of the corresponding cis ether 33, the rapid cis → trans isomerisation of this ether and the cis/trans ratio of the phenol 34 indicate that the reverse rearrangement of the intermediate ortho-dienone to the ether 33 and the further rearrangement to 4-crotyl-2,6-dimethyl-phenol (34) has little stereoselective character.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0018-019X
    Keywords: Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The mechanism of the abnormal CLAISEN rearrangement, that is the isomerisation of o-allylphenols, has been investigated using deuterium as tracer. The incorporation and distribution of the label was followed by proton and deuterium NMR. analysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...