Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (4)
  • 1940-1944
  • Analytical Chemistry and Spectroscopy  (3)
  • Computer package  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Euphytica 33 (1984), S. 935-942 
    ISSN: 1573-5060
    Keywords: Computer package ; data base ; data manipulation ; field trials ; plant breeding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary A computer data base package, specifically designed to be used to store data collected from a plant breeding programme is described. The package will do many of the routine clerical operations involved in plant breeding, such as producing plot labels, field plans, genotype lists and data tabulations. It also has several statistical analysis routines, and routines which allow the user to examine and manipulate data. The package is user friendly since it was designed to be operated by plant breeders rather than computing specialists. Although it was written to handle data collected from a plant breeding programme, the package is flexible and could be used for a number of different applications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 10 (1981), S. 153-153 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 10 (1981), S. 138-146 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: It is shown that the depth distribution of X-ray production in the electron microprobe can be accurately described by a Gaussian modified at the sample surface by a transient. Assuming that the Gaussian is a consequence of the electrons undergoing a random walk in the sample and that the transient corresponds with the change from collimated to random electron trajectories enables theoretical values for the amplitudes and coefficients of the two functions to be predicted. There is excellent agreement between the predicted and the observed values. The Lenard coefficient and the electron range can both be estimated from the coefficient in the Gaussian. It is suggested that for microprobe work, Lenard's law for electron absorption be replaced by this revised law. Both the absorption and atomic number corrections of the traditional ZAF approach are replaced by the new function.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 11 (1982), S. 187-193 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The Gaussian expression for φ(ρz) has been used as the basis of a computer program for quantitative electron probe microanalysis. Corrections for absorption and atomic number are combined within the expression for φ(ρz) whereas the fluorescence correction is based on numerical integration over the primary and secondary intensities. Error histograms based on about 500 published analyses of standard specimens have been used to adjust the parameters in the Gaussian expression for optimum accuracy. The resultant error histograms are as narrow as those obtained for the most accurate of the current ZAF correction procedures. Extension of the method to non-normal electron incidence is relatively straightforward.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...