Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (1)
  • 1940-1944
  • Sewage ponds  (1)
Material
Years
  • 1980-1984  (1)
  • 1940-1944
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Hydrobiologia 72 (1980), S. 21-30 
    ISSN: 1573-5117
    Keywords: Sewage ponds ; BOD-removal ; stability ; Daphnia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract By arranging sewage ponds in series, some feedback relationships within the food web are disconnected, but stability may increase. This particularly applies to a persistent ‘clearwater-state’ in the last cell caused by mass growths of Daphnia or other zooplankton in the absence of fish. Microbial pollution in this case is reduced to a level which may permit nearly unrestricted irrigation. The oxygen balance of lagoons is, apart from the diurnal cycle, subject to substantial temporal variations. This also applies to continuous-flow laboratory models with a constant (BOD-load, temperature) or a constant-cycle (light) chemical and physical environment. An example is given illustrating a high adjustment stability of a lagoon in consequence of a catastrophic perturbation. The strong tendency of lagoons towards an oligomictic behaviour is promoted by thermal stratification and by a vertical gradient in the metabolic activity (oxidation/reduction potential). The hydrodynamic conditions oscillate between plug flow in periods of convective overturn and short-circuiting if thermal stratification has developed. Nevertheless, the average performance (BOD removal) for a particular season could be calculated with a reasonable accuracy. As a basis for this calculation, nomographs were developed from which the rate coefficient K1 of BOD removal for a given combination of residence time and BOD load can be read.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...