Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1980-1984  (6)
  • 1935-1939
  • 1890-1899
  • 1830-1839
  • Chemical Engineering  (4)
  • Bone  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 34 (1982), S. 439-448 
    ISSN: 1432-0827
    Schlagwort(e): Bone ; Histomorphometry ; Osteocytes ; Bone dynamics ; Histology
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Summary A new semiautomatic technique combining advantages of the manual and fully automatic methods is described for obtaining quantitative static and dynamic histologic data of bone. The hardware consists of a photomicroscope, digitizing platen, digitizer, plotter/printer, floppy disc drive, and computer. The microscope is equipped with a drawing tube through which the image of the digitizing platen is projected over the optical field. The investigator selects and traces all histologic structures to be measured by moving a cursor on the digitizing platen which is visible by its projection over the histologic field. The results on accuracy and static and dynamic precision of this method show that static and dynamic parameters of bone are obtained with a degree of error (〈20%) well within the acceptable range for biologic measurements. Comparison of this method with the grid technique according to Merz and Schenck showed that for almost all micromorphometric parameters comparable absolute data are obtained. Due to the higher precision of our method, however, the number of optical fields evaluated in obtaining these comparable data could be reduced to 25% of the number of fields evaluated by the Merz and Schenck technique. The time requirements for quantitative evaluation of a histologic slide of bone by our technique are 40–50 min; 20–25 min is needed for quantitative evaluation of osteocytes.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 34 (1982), S. 449-455 
    ISSN: 1432-0827
    Schlagwort(e): Bone ; Histomorphometry ; Normal values ; Bone biopsies ; Sampling error
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Summary Quantitative bone histology was done in undecalcified sections of iliac crest bone specimens obtained from 84 normal American individuals. Samples were obtained within 12 h after death in a vertical and horizontal manner from both the right and left iliac crests. In addition to the determination of normal values of micromorphometric parameters of bone in these healthy American subjects, the following studies were carried out: (a) comparison of variance of micromorphometric parameters of bone obtained from the right versus left iliac bone (40 pairs), (b) comparison of micromorphometric parameters of bone obtained in a vertical versus horizontal manner (12 pairs), (c) evaluation of variance with increasing distance from the compact zone in bone samples obtained in a vertical manner (44 pairs), (d) analysis of variation between bone samples obtained more anteriorly versus posteriorly along the iliac crest (N=40), (e) comparison of differences in micromorphometric parameters obtained from age-matched men versus premenopausal women (N=12), and (f) plotting of histograms for assessment of distribution of micromorphometric parameters. The results show that histomorphometric data of bone cannot be easily compared when different techniques are employed for obtaining bone samples. Sampling variations are kept smaller when bone specimens are obtained in a vertical manner. Anterior/posterior variation does not cause major sampling error. If ranges of variation are taken into account, quantitative bone histology is a valuable tool for assessment of bone structure and bone cells.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 26 (1980), S. 363-371 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: An analysis is made of centrifugal flow of compacted porous beds through channels against high gas backpressure. One-dimensional compressible gas flow solutions are presented for concurrent and countercurrent solids/gas motion through the variable area channels. The physical process analyzed represents the flow through a newly developed centrifugal pump for feeding dry pulverized material against a pressure barrier. The objective of the analysis is to gain a basic theoretical understanding of this type of device. Good agreement is found between analytical predictions and test data obtained with an experimental pump feeding coal.
    Zusätzliches Material: 18 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 0032-3888
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: This work shows how laboratory experiments may provide parameters which are useful in modeling a commercial process of polystyrene devolatilization. Such processes often occur at temperatures where depolymerization of polystyrene to monomer may be significant. Polystyrene devolatilizers function by forming thin films of the polymer, with styrene loss by flashing and diffusion and styrene generation by depolymerization. The modeling parameters of importance are: depolymerization rate constant, monomer diffusivity, and thermodynamic equilibrium polymer-vapor partition coefficient. Typical levels of styrene in polystyrene in the last stage of devolatilization are 100 to 1000 ppm. Pressures and temperatures in the devolatilizer are often less than 10 torr and greater than 200°C. For styrene-polystyrene the desired parameters have not been reported, nor apparently measured, at the concentration, pressure and temperature levels of interest.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 23 (1983), S. 394-398 
    ISSN: 0032-3888
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The mechanical behavior of polyurethane-poly(methyl methacrylate) interpenetrating polymer networks (PUR/PAc IPN's) was investigated. Stress-strain and impact resistance measurements were made on IPN's with a variable PUR content. The effect of the degree of crosslinking of each network on the mechanical properties was also studied. It appears that only the ultimate elongation varies largely upon changing the crosslink degree. The results are interpreted in terms of the contribution of each network to the mechanical behavior, but also by the interpenetration of both components and by the phase continuity of the PAc network.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Brookfield, Conn. : Wiley-Blackwell
    Polymer Composites 1 (1980), S. 37-43 
    ISSN: 0272-8397
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Maschinenbau
    Notizen: Mineral fillers of flake configuration such as mica can, in principle, produce large increases in modulus and strength especially if the flake is oriented predominantly in a plane. Additionally, the resulting composites have the advantage of possessing isotropic properties in the plane of orientation, thereby minimizing the warpage normally associated with the injection molding of fiber-reinforced thermoplastics. However, to properly transmit stress from the matrix to the mica and minimize the effect of defects in morphology, a ductile matrix is required with adequate interaction or adhesion between phases. Many of the above conclusions are documented in the literature and are confirmed by our investigations of the system mica-polypropylene. The novelty of this effort rests upon (1) successful attempts to identify specific non-silane additives which by co-blending suitably modify the mica-polypropylene interface, (2) to demonstrate the remarkable effects of time-temperature during melt processing on the behavior of this system; and, (3) to show the relation between composition and time-temperature effects on resultant mechanical, physical, and thermal properties. Most notably, large improvements in tensile and flexural strength and heat distortion temperature can be attributed to the use of small amounts of chlorinated organic compounds blended under carefully selected melt process conditions. Some speculation concerning the mechanism of interaction will be discussed and the resultant potential for increased application will also be outlined.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...