Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (4)
  • 42.80  (2)
  • norepinephrine  (2)
  • Motilin
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 24 (1981), S. 331-340 
    ISSN: 1432-0630
    Keywords: 06.60 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A full-automatic wavelength controled pulsed dye laser has been developed. With the control system, dye laser oscillations of nanosecond pulses are tuned to any wavelength in the visible or scanned in any sweep mode keeping the nearly transform-limited bandwidth of 0.45 GHz. A mechanical tuning of the wavelength is employed, such that the motion of three wavelength selectors is synchronized to give a smooth and precise wavelength control. The basic principle underlying the tuning scheme, various requirements to be met in system construction, and the practical performance of automatic wavelength control are described in this paper.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 25 (1981), S. 311-316 
    ISSN: 1432-0630
    Keywords: 07.40 ; 07.60 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract A high precision wavelength meter in the visible is described, which is based on a Fabry-Perot interferometer with several etalons of different resolution. The interference fringe pattern projected on a photo-diode array detector is computationally processed to give a stepwise refinement of the wavelength value to any adjusted accuracy. The present model intends to provide digital and real-time values of high precision wavelength for dye-laser spectroscopy, and to serve as a monitor or as a pilot for wavelength control of a dye-laser source of nanosecond pulses. The model is, therefore, designed with particular emphasis on its short-pulse capability and on-line mode of operation as well as on its high sensitivity and resolution. Some arrangements of essential necessity are involved therein, such as to avoid an errorneous wavelength readout for a noisy incidence of pulsed field. The ultimate accuracy of wavelength measurement is prescribed by the resolving power of the thickest etalon employed. As applied to the pulsed source, the model determines the wavelength to the accuracy of ±one part in 107 for even a single shot nanosecond incidence of a fraction of μJ energy. The design and performance are described in connection to pulsed dye-laser incidence.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1041
    Keywords: L-threo-3,4-dihydroxyphenylserine ; norepinephrine ; octopamine ; dopamine-β-hydroxylase ; familial amyloid polyneuropathy denervation supersensitivity ; autonomic dysfunction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary L-threo-3,4-dihydroxyphenylserine (DOPS), an immediate precursor amino acid of (-)-norepinephrine, was used as a pharmacological tool to investigate the pathophysiology of the peripheral sympathetic nervous system in Type 1 familial amyloid polyneuropathy. Patients with the well-established disorder showed an enhanced pressor reponse to L-threo-DOPS under conditions that produced no change in normal subjects. While octopamine induced a brisk pressor response, L-threo-DOPS produced a slow and prolonged change in blood pressure, with a marked concomitant increase in urinary excretion of norepinephrine. A slight increase in urinary excretion of total metanephrine was observed in both groups, but there was no significant increase in serum dopamine-β-hydroxylase activity. Since infusion of dilute norepinephrine into patients also produced a markedly hypersensitive response, the characteristic pressor response to L-threo-DOPS was indicative of denervation supersensitivity of adrenergic receptors to norepinephrine formed enzymatically from L-threo-DOPS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1041
    Keywords: L-threo-3,4-dihydroxyphenylserine ; familial amyloid polyneuropathy ; pharmacokinetics ; norepinephrine ; pressor response
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The pharmacokinetics of oralL-threo-3,4-dihydroxyphenylserine (L-threo-DOPS) was studied in 7 normal subjects and 7 patients with familial amyloid polyneuropathy. Each person swallowed a single 300 mg dose in the fasting state, andL-threo-DOPS in plasma and urine was determined by high performance liquid chromatography with an electrochemical detector after separation on a boric acid gel column.L-threo-DOPS was slowly absorbed by normal subjects; the maximum plasma concentration occurred 3 h after administration and 20% of the oral dose was recovered unchanged in the urine within 12 h. It induced a substantial elevation of plasma norepinephrine levels, the peak being attained at 5 h, but without any change in blood pressure. In the patients, the absorption and metabolism ofL-threo-DOPS were delayed, and a prolonged pressor response was observed, with a peak after 8 h. It was concluded that the effects on plasma norepinephrine and blood pressure of oralL-threo-DOPS were essentially equal to those of twice as large a dose ofDl-threo-DOPS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...