    Journal of nondestructive evaluation 2 (1981), S. 23-33 
    ISSN: 1573-4862
    Keywords: austenitic stainless steel ; austenitic stainless steel welds ; eddy current inspection ; eddy current testing ; electromagnetic testing ; ferromagnetic steel inspection ; flaw characterization ; flaw detection ; NDE ; multifrequency eddy current inspection ; weld inspection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract This paper describes the initial phase of a project to develop eddy-current methods to inspect welds joining sections of austenitic stainless steel pipe having walls up to 13 mm (0.5 in.) thick. The objective of this phase was to demonstrate the feasibility of detecting and characterizing flaws in austenitic stainless steel base metals. These materials and welds present challenging eddy-current problems because of their relatively large thickness and ferromagnetism. Multiparameter analysis shows that a reflection coil probe operated with three discrete driver frequencies and phase detection can locate and size a cracklike defect in a single conductor in the presence of variations in conductor resistivity, permeability, and thickness and in the probe-conductor spacing (liftoff). Experiments were performed with a modular three-frequency instrument. Flat-plate specimens of types 304L and 347 stainless steel machined to 12.7 to 15.9 mm thickness simulated pipe walls; saw-cut slots 10 to 30% of nominal specimen thickness simulated cracklike defects. The same slots were used in duplicate experiments as near-side (directly under the test probe) or far-side (in the face opposite the probe) defects. Flaw detection and characterization capability was demonstrated by a series of experimental measurements fitted to specimen properties by least squares techniques. The quality of the fit determined the expected accuracy of measurement. Comparison of accuracy estimates determined the best choice of operating frequencies. From the 1,2,5 sequence of frequencies between 0.5 and 20 kHz, the optimum set of operating frequencies was selected to be 0.5, 2, and 10 kHz. Estimates of measurement accuracy for combined near- and far-side defect cases were: plate thickness, 0.74 mm; probe liftoff, 0.03 mm; defect location (depth of material above defect), 3.48 mm; and defect size (vertical slot depth), 1.09 mm. A few property values were back-calculated from instrument readings; the errors in these values were somewhat larger than the measurement accuracy estimates because of instrument drift and the absence of calibration circuits.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 2581-2592 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: ABS masterbatch concentrates in antioxidants and UV stabilizers were added as conventional additives for normal ABS. The thermal and photo-oxidative performance of these polymers were compared with that of the commercial ABS and additives by measurement of carbonyl index and embrittlement times. From the result obtained, it is concluded that the addition of these additives in the form of masterbatches appears to be a better practical way of incorporating antioxidants and UV stabilizers into ABS simply by dilution of ABS, as these give thermal and light-stabilizing effects that cannot be achieved by stabilizers added in a conventional way. The bound stabilizers are resistant to leaching and chemical extraction.