Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2072
    Keywords: Residual effects ; Polygraphy 24 h ; Triazolam ; Flurazepam ; Nitrazepam
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The residual effects of three hypnotics were investigated by the method of 24-h polygraphy (EEG, EMG, and EOG). The drugs were triazolam 0.25 mg and 0.5 mg, flurazepam 15 mg and 30 mg, nitrazepam 5 mg and 10 mg, and placebo. The subjects were healthy volunteers, eight men and eight women with an average age of 34.3 years. The number of total polygraphic records was 77. Triazolam 0.25 mg and 0.5 mg, flurazepam 30 mg, and nitrazepam 10 mg showed definite sleep inducing and sleep maintenance effects in night recordings. Flurazepam 15 mg and 30 mg and nitrazepam 5 mg and 10 mg were followed by residual effects in morning, afternoon and evening recording periods on the day after the administrations of the hypnotics. However, no effects were seen on the day after the administration of triazolam 0.25 mg and 0.5 mg except for some slight residual effects in the morning. Thus triazolam 0.25 mg and 0.5 mg produces less residual effect than do flurazepam 15 mg and 30 mg, and nitrazepam 5 mg and 10 mg, and 24-h polygraphy is useful for measuring the residual effects of hypnotics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1435-1528
    Keywords: Non-Newtonian fluid ; pulsating flow ; oscillating flow ; concentric cylinders ; eccentric cylinders
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Abstract The unsteady flow of non-Newtonian fluids through concentric and eccentric cylinders was investigated experimentally. Two experiments were carried out; one was pulsating flow and the other was flow under a constant pressure gradient with the inner cylinder oscillating longitudinally. The flow enhancement was examined and its dependence on the frequency of the oscillations and the eccentricity of the apparatus was determined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...