Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (5)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Theory of computing systems 17 (1984), S. 335-350 
    ISSN: 1433-0490
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Notes: Abstract This is the first of two papers concerned with the formulation of a continuous-time quantum-mechanical filter. Efforts focus on a quantum system with Hamiltonian of the formH 0+u(t)H 1, whereH 0 is the Hamiltonian of the undisturbed system,H 1 is a system observable which couples to an external classical field, andu(t) represents the time-varying signal impressed by this field. An important problem is to determine when and how the signalu(t) can be extracted from the time-development of the measured value of a suitable system observableC (invertibility problem). There exist certain quasiclassical observables such that the expected value and the measured value can be made to coincide. These are called quantum nondemolition observables. The invertibility problem is posed and solved for such observables. Since the physical quantum-mechanical system must be modelled as aninfinite-dimensional bilinear system, the domain issue for the operatorsH 0,H 1, andC becomes nontrivial. This technical matter is dealt with by invoking the concept of an analytic domain. An additional complication is that the output observableC is in general time-dependent.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 305 (1982), S. 223-229 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Proceeding from a least-action principle, a generalization of the random-phase approximation is developed which is suited to the description of elementary excitations in such strongly-interacting Fermi systems as nuclei, nuclear matter, neutron-star matter and liquid3He. The equations of the theory involve matrix elements of the Hamiltonian and identity operators in a nonorthogonal basis of states incorporating short-range correlations. Linear response of the dynamically correlated system to a weak external perturbation is investigated within the same framework.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 305 (1982), S. 367-367 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-9686
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Conventional peripherally invasive mechanical circulatory assist methods such as intra-aortic balloon pumping are of only limited hemodynamic benefit in cases of severe left ventricular failure. This article deals with the analysis and testing of a new pumping concept (16), that is theoretically capable of providing adequate circulatory and respiratory assistance in cases of severe uni- or biventricular failure. This assist system combines an intra-aortic balloon pump (a series form of left ventricular assistance) and pulsatile venoarterial membrane oxygenator bypass (a parallel mode of assistance). The combined pulsatile assist system is controlled by a digital microprocessor which provides appropriate phasing relative to the R wave of the ECG. This support system requires only cannulation of femoral or other easily exposed vessels. Blood-gas exchange gas diffusion or massive pulmonary embolism or other perfusion defects. This concept has been tested in a series of experiments with canine models of ventricular failure. The results of this study indicate that (1) balloon pumping becomes much more effective when combined with pulsatile veno-arterial bypass in cases of severe ventricular failure with an attendant hypotensive circulatory state, and (2) the automatic control system is effective in optimizing the performance of the combined assist system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 8 (1980), S. 209-224 
    ISSN: 1573-9686
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract An automatic control scheme for the control of intra-aortic balloon pumping has been implemented on a Digital Equipment Corporation LSI-11 micro-processor system and tested in experiments conducted on a mock circulatory loop as well as in a series of acute animal experiments. The control algorithm employed by the digital controller (LSI-11) is identical in form to that employed by Clark et al. (3), and consists of [1] the beat-by-beat evaluation of a performance index that reflects the objectives of balloon pumping, and [2] the adjustment of balloon inflation and deflation times within the diastolic period so as to maximize this performance index according to a steepest ascent algorithm. In order to reduce convergence time and minimize disturbances around the optimum operating point, a scheme that reduces search step size as the search proceeds from initial values is also incorporated in the algorithm. Importantly, this system obeys a bedside measurement constraint in that it requires only readily available physiologic signals for its operation; the ECG for timing purposes, and the central aortic pressure for evaluation of the system performance index. A number of conventional safety features are also implemented in the controller to, for example, guard against untimely balloon inflation in the occurrence of aberrant heart beats. Finally, the ability of this digital controller to reach an optimum independent of the dynamics of the particular pneumatic pumping system utilized, coupled with the flexibility in design capability and relatively low cost of implementation via the microprocessor system, provide a significant advance in the area of the automatic control of intra-aortic balloon pumping.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...