Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (2)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 48 (1983), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The effect of high voltage electrical stimulation (800V RMS, 10 ms pulse width, 14.3 Hz for 90 sec) on the tenderization due to aging of meat at 0— 1°C has been studied by obtaining Warner-Bratzler shear force deformation curves of cooked longissimus dorsi and semimembranosus muscles from young and old sheep. For muscles restrained from myofibrillar shortening stimulation did not result in any significant improvement in shear parameters nor was the aging process affected. For muscles able to shorten, stimulation produced a substantial reduction in shear force values to the level obtained for restrained muscle. Shear force measurements on samples pressure-heat treated, to minimize myofibrillar strength, indicated that major structural changes in connective tissue, due to electrical stimulation, were unlikely.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 47 (1982), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A comparison has been made between two Warner-Bratzler (WB) shear devices, differing in their method of operation, used in measuring tenderness of meat samples treated to produce a wide range, in both myofibrillar and connective tissue structural strength. Estimates of parameters measured from the shear deformation curves obtained from the two systems were highly correlated and both systems showed similar and significant responses to the treatments used to modify the structural components of meat.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...