Electronic Resource
Copenhagen
:
International Union of Crystallography (IUCr)
Applied crystallography online
16 (1983), S. 524-531
ISSN:
1600-5767
Source:
Crystallography Journals Online : IUCR Backfile Archive 1948-2001
Topics:
Geosciences
,
Physics
Notes:
The principal methods of employing double-crystal reflection for harmonic rejection are briefly reviewed. The effect of using non-equal d spacings (dispersion) is considered. A new type of perfect-crystal monochromator consisting of a monolithic combination of a pair of grooved crystals a and b is described. The monochromaticity (degree of harmonic suppression) M(β) is tuned by tilting groove a with respect to groove b by an appropriate angle β. The tilting is achieved in a simple way through a pair of helical springs. With three reflections in the first and two reflections in the second groove M(β0) values between about 300 and 100 have been measured for X-rays at energies ranging from 6.72 to 9.86 keV and at a bandwidth ΔE/E∼1.5%. β0 is the tilting angle for which M(β) is optimized. Once aligned the monochromator is a very simple unit, which can be mounted on any standard goniometer head and which can be used for both X-rays and thermal neutrons.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1107/S0021889883010948
Permalink
Library |
Location |
Call Number |
Volume/Issue/Year |
Availability |