    Pharmacy world & science 3 (1981), S. 1285-1301 
    ISSN: 1573-739X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Good Manufacturing Practice (GMP) is concerned with both manufacturing and quality control procedures. Good radiopharmacy practice means GMP applied to radiopharmaceuticals by taking into account the special nature of these products. Because radioactive substances are the essential basis for the acquisition of data from nuclear medicine investigations, attention has to be paid to the control of all parameters of quality assurance. This is particularly important in those cases where quality control tests have to be performed on apost factum basis,i.e. after administration to the patient, because of the short half-life time of the radionuclide. Radiopharmaceutical quality control is a necessity in all nuclear medicine departments. If a laboratory does not institute radiopharmaceutical quality control until the cause of a ‘poor image’ in the diagnostic process must be identified, the problem will be compounded. The quality control tests must be mastered before they can be used to resolve problems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract 57Co-bleomycin is useful in the detection and staging of lung cancer, but the long half-life of 57Co (270 days) has discouraged its widespread acceptance. We investigated the shorter living positron emitting 55Co (half-life 18.2 h) as a label for bleomycin. In eleven patients with proven lung cancer scintigraphy with 55Co-bleomycin, using a positron camera, demonstrated the tumor in ten cases. Tumor to lung ratios were calculated. The results were superior to those obtained with 55Co-bleomycin single photon imaging but inferior to those obtained with 57Co-bleomycin scintigraphy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The level of the aminoterminal propeptide Col 1–3 of type III procollagen (PC-III) was determined in patients with paroxysmal nocturnal haemoglobinuria (PNH) and primary myelofibrosis (PMF), to study whether PC-III can be used as a parameter for the rate and/or degree of bone marrow replacement with collagen. Normal PC-III levels were found in PNH (6.6±1.1 μg/l; N: 8.6±1.8 μg/l), while significantly increased levels were found in PMF (24.8±2.2 μg/l). During a follow-up of 1 year, a slight increase of 2 μg/l occurred in three patients with a stable fibrosis, while one patient with more active disease demonstrated an increase of 25 μg/l. Treatment with acetylsalicylic acid led to a decline of PC-III as well as β-thromboglobulin level, although normalization did not occur. It was demonstrated by means of gel filtration that the antigens related to the PC-III peptide were heterogenous, and that in PMF at least two main peaks were present, with molecular masses equal to and smaller than PC-III peptide. These data demonstrate that the radioimmunoassay cannot be used for the quantitative determination of PC-III; nevertheless it gives some insight in the process of bone marrow fibrosis.