Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1975-1979  (1)
  • 1960-1964  (2)
  • 1935-1939
  • Chemistry  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 6 (1960), S. 145-149 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The transfer rates of n-butanol, cyclohexanol, and ethyl acetate into water drops have been measured for circulating and oscillating drops.Methods of allowing for the end-effect transfer have been extended and measured values compared with predictions of a model.Various mechanisms for transfer inside drops have been examined in terms of a correlation factor.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 6 (1960), S. 373-381 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The performance of sieve trays in the rectification of the methanol-water system without entrainment or leakage from the perforations was studied in an 8-in.-diameter five-tray column. The trays had a 2-in. weir height and 4-in. length of liquid path. Three tray geometries were studied: 1/4-in. diameter holes on 3/4-in. triangular spacing, 1/8-in. holes on 3/8-in. triangular spacing, and 3/16-in. on 7/16-in. triangular spacing. The superficial vapor velocity was varied from 2.2 ft./sec. to the limit of stable operation, which for this apparatus was 4.4 ft./sec. The ratio LM/VM within the column was varied from 1 to 0.5. The Murphree plate efficiency varied greatly from 105% at low concentration to 82% at high concentrations of methanol. Variations of 10 or 12 efficiency % were noted owing to changing velocities and tray geometries. Measurements of concentration gradients, foam heights, and gas pressure drops are also reported. This paper proposes a method of calculating the point efficiency and the number of individual-phase mass transfer units independent of the actual concentration gradient on the tray.The method is applied to the methanol-water data, and calculated point efficiencies range from 50 to 65%. The value of 1/NL for the methanol-water system is found to be small. The values of NG and the effect of the velocity on NG are believed to be the first in the literature for a tray in distillation operation. The effect of velocity is shown to be in agreement with the theory proposed by Gerster and co-workers. It is shown that kG' aG decreases for increasing free area and increasing hole size. Finally variation in LM/VM is shown to have little effect on EMV.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 10 (1976), S. 695-731 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biocompatibility of nitinol alloy as a potential implant material was investigated through in vivo studies on beagles. A high-purity alloy was fabricated into prototype bone plates and implanted into the femurs of beagles. Commercial cobalt-chromium (Co—Cr) alloy bone plates served as reference controls, and additional control data were obtained from beagles subjected to “sham” operations.The bone plates were removed from the animals and examined after exposures of 3, 6, 12, and 17 months. There was no evidence of either localized or of general corrosion on the surfaces of the bone plates and screws. Gross clinical, radiological, and morphological observations of the tissue at the implantation sites during the autopsies uncovered no signs of adverse tissue reactions resulting from the implants. Histological analyses were performed on samples of muscle and bone adjacent to the implantation sites, and of tissues removed from such organs as the liver, spleen, brain, and kidneys. No significant differences were noted between samples taken from controls and those taken from dogs exposed to the implants. Neutron activation analyses were carried out on suitable samples. The analysis data suggest that there is no metallic contamination in the organs due to the implants; however, there does appear to be some chromium contamination from the Co—Cr alloy implants in the adjacent bone.On the basis of the totality of the data, it is concluded that nitinol alloy is sufficiently compatible with dog tissue to warrant further investigation of its potential as a biomaterial.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...