Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1975-1979  (2)
  • 1960-1964
  • Flow-autoregulation  (1)
  • Guidelines for an effective solvent effect, in literature citation  (1)
  • 1
    ISSN: 1432-2013
    Keywords: Flow-autoregulation ; Ventricular function ; External heart work ; Myocardial oxygen consumption ; Efficiency ; Pyruvate decarboxylation ; Noradrenaline
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cardiac performance and some parameters of glycolytic and oxidative metabolism were analyzed in isolated perfused guinea pig hearts performing pressure-volume work. Perfusion medium was an oxygenated Krebs-Henseleit bicarbonate buffer (pH 7.4) which contained glucose and physiological concentrations of pyruvate and insulin. The pressure-flow relationship in the coronary vascular bed indicated autoregulation of coronary flow. Left ventricular function was influenced by aortic pressure (Pa) and venous filling pressure (Pv) in accordance with the Frank-Starling principle, i.e. stroke work increased as a function of Pa or Pv to a certain maximum and then decreased. Myocardial oxygen consumption (MVO2), on the other hand, was linearly correlated with Pa and Pv, respectively, over the entire pressure range. Efficiency of the left ventricle, therefore, increased to an optimum (16%) and decreased at higher pressures. Myocardial contents of glycogen, ATP and creatine phosphate were not markedly influenced by a change in Pa or Pv.l-Noradrenaline (0.08 μM, NA) stimulated stroke work and MVO2 at a all Pv tested; efficiencies reached physiologic values (21%) at high volume loads. The increased MVO2 was associated with an acceleration of pyruvate decarboxylation and lactate release up to 10- and 15-fold, respectively, at elevated but physiological NA concentrations (0.2 μM). Our results demonstrate that the isolated perfused working guinea pig heart compares favourably with the non-failing Starling heart-lung preparation and hearts in situ, as far as coronary function, left ventricular performance and oxidative metabolism are concerned.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 275-276 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary ; Splitless injection ; Theoretical basis for reconcetration by solvent effects ; Guidelines for an effective solvent effect, in literature citation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...