Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1970-1974  (2)
  • Tetanus  (2)
  • Depolarization
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 281 (1974), S. 47-56 
    ISSN: 1432-1912
    Keywords: Botulinum A ; Tetanus ; Neurotoxin ; Hemagglutinin ; Iodine Labeling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary 1. Labeling of crystalline botulinum A toxin has been done with 125I by aid of the chloramine T method. The neurotoxic component is well preserved, whereas the hemagglutinin undergoes physicochemical alterations. Neither with labeled nor with unlabeled toxin, hemagglutinating power parallels the main protein peak. 2. Neurotoxin, homogeneous in gel filtration, is bound to synaptosomes from rat brain. Cold toxin competes with labeled toxin, and antitoxin or neuraminidase partially remove the bound neurotoxin. 3. Upon intramuscular injection, some radioactivity is recovered in the respective parts of the spinal cord. Antitoxin prevents the ascent. The similarities between tetanus and botulinum A neurotoxins are stressed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 276 (1973), S. 321-326 
    ISSN: 1432-1912
    Keywords: Tetanus ; Antibodies ; Radioimmunological Measurement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A radioimmunological assay procedure allows the measurement of small amounts of tetanus antibodies; it should also be applicable to antibodies against other soluble antigens. It is based on the competition between dissolved and solid phase antibodies for labelled antigen. In the range of experimental error, the same antibody titers are found with the radioimmunological and with the mouse protection test. The detection limit is in the range of 0.001 IU/ml. The reaction conditions allow the determination of antibodies in multiple samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...