Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • (Rat)  (1)
  • Antibody production  (1)
  • Cervical spine  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/Protein Structure and Molecular 1037 (1990), S. 155-160 
    ISSN: 0167-4838
    Keywords: (Rainbow trout) ; (Rat) ; Cytochrome P-450 ; Immunochemical homology
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2048
    Keywords: Antibody production ; Enzyme immunolocalization ; Lilium ; Phosphoglycerate mutase (cofactor independent) ; Vitronectin antibody
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract A cofactor-independent phosphoglycerate mutase (PGAM-i) was isolated to homogeneity from monocotyledonous Lilium longiflorum Thunb. Two-dimensional (2D) polyacrylamide gel electrophoresis resolved three PGAM-i forms. This enzyme was originally identified by cross-reactivity to antibodies affinity-purified from 2D gels using human vitronectin (VN). Antibody produced against a denatured protein spot from a 2D gel did not recognize VN protein, but partial protein and DNA sequencing showed similarity of the former protein to maize PGAM-i. Immunoblots from roots, styles, leaves, and anthers showed the presence of PGAM-i in all tissues examined; it was isolated predominantly from the soluble cell fraction, with some present in the insoluble cell fraction. Immunoelectron microscopy demonstrated its localization in the cytoplasm and plastids in root cells near the apical meristem. In addition, immunogold labeling detected signals from the nucleus. The immunohistochemical localization of the enzyme in the nucleus, as well as in the cytosol and plastids, indicates that lily PGAM-i might have multiple functions in the cell.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0932
    Keywords: Key words Anatomy ; Pedicles ; Cervical spine ; Pedicle ¶instrumentation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Transpedicular screw fixation has recently been shown to be successful in stabilizing the middle and lower cervical spine. Controversy exists, however, over its efficacy, due to the smaller size of cervical pedicles and the proximity of significant neurovascular structures to both lateral and medial cortical walls. To aid the spinal surgeon in the insertion of pedicle screws, a number of studies have been performed to quantify the gross dimensions and angulations of the cervical pedicle. Notwithstanding these quantitative studies, there has been a conspicuous absence of research reporting the qualitative characteristics of the cervical pedicle. The purpose of our study was to provide comparative graphical data that would systematically document the anatomic variability in cervical pedicle morphology. Such information should better elucidate the complexity of the pedicle as a three-dimensional structure and provide the spinal surgeon with a more complete understanding of cervical pedicle architecture. Twenty-six human cervical vertebrae (C3–C7) from six fresh-frozen spines were secured to a thin sectioning apparatus to produce three 0.7-mm- thick pedicle slices along its axis. Radiographs taken of these pedicle slices were scanned, digitized, and traced to facilitate visual comparison. The pedicle slices were found to exhibit substantial variability in composition and shape, not only between individual spines and vertebral levels, but also within the pedicle axis. However, the lateral cortex was consistently found to be thinner than the medial cortex in all samples. These physical findings must be noted by surgeons attempting transpedicular screw fixation in the cervical spine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...