Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 35.10.Bg  (2)
  • 35.10.F  (2)
  • 07.65  (1)
  • 21.10.-k  (1)
Material
Years
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 321 (1985), S. 537-547 
    ISSN: 1434-601X
    Keywords: 21.10.-k ; 27.80+w ; 31.30.Gs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The isotope shift between197Au (stable) and the radioactive Au isotopes190Au,191Au,192Au and193Au were determined by resonance fluorescence spectroscopy in the 6s 2 S 1/2–6p 2 P 1/2.λ=267.6nm line. The unstable Au isotopes were produced at the ISOLDE mass separator at CERN. The nuclei were investigated semi on-line in a resonance vessel, heated to 1,400°C. The results areδν 190,197=−11.12(39) GHz,δν 191,197=−9.67(12) GHz,δν 192,197=−8.32(15) GHz,δν 193,197=−6.29(11) GHz, corresponding to a change of the mean-square charge radius byδ〈r 2〉190,197 =0.261(12) fm2,δ〈r 2〉191,197=0.227(5) fm2,δ〈r 2〉192,197=0.195(5) fm2,δ〈r 2〉193,197 =0.148(4) fm2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0649
    Keywords: 32 ; 42.60 ; 07.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Laser photoionization has been used to detect trace amounts of plutonium. A high sensitivity and selectivity has been achieved by applying three-step excitation and ionization of the plutonium atoms with high pulse-repetition rates and additional mass determination by time-of-flight measurements. A laser system was developed which consists of a copper vapor laser pumping three dye lasers simultaneously. Samples containing between 1010 and 1012 atoms of239Pu on Re filaments were measured yielding strong resonance signals with maximum ion count rates of several kHz at a vanishingly low background. A detection efficiency of 10−7 was determined allowing the detection of about 108 plutonium atoms in a sample.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Keywords: 21.10 ; 21.60 ; 27.70 ; 27.80 ; 35.10.F
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The hyperfine structure splitting and the isotope shift in the λ=266 nm transition of Pt isotopes within the mass range 183 ≦A≦ 198 have been determined by Resonance Ionization Mass Spectroscopy (RIMS) in combination with Pulsed-Laser Induced Desorption (PLID). The Pt isotopes were obtained at the on-line isotope separator ISOLDE-3/CERN as daugthers of the primarily produced Hg isotopes. Magnetic moments, quadrupole moments, and changes in the mean-square charge radii are deduced and compared with results of a particle-triaxial rotor model and mean field calculations. Good agreement with experimental data (including nuclear level schemes and transition probabilities) can only be obtained if triaxial shape is admitted. The calculations yield a smooth transition in the shape of odd-A Pt nuclei from a slightly deformed, nearly oblate195Pt via triaxial197-187Pt to a strongly deformed nearly prolate177Pt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-6079
    Keywords: 31.30.G ; 31.30.J ; 35.10.F ; 42.65.C
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The hyperfine structure and isotope shift of221–226Ra and212,214Ra have been measured in the ionic (Ra II) transition 7s 2 S 1/2–7p 2 P 3/2 (λ=381.4 nm). The method of on-line collinear fast-beam laser spectroscopy has been applied using frequency-doubling of cw dye laser radiation in an external ring cavity. The magnetic hyperfine fields are compared with semi-empirical and ab initio calculations. The analysis of the quadrupole splitting by the same method yields the following, improved values of spectroscopic quadrupole moments:Q s (221Ra)=1.978(7)b,Q s (223Ra)=1.254(3)b and the reanalyzed valuesQ s (209Ra)=0.40(2)b,Q s (211Ra)=0.48(2)b,Q s (227Ra)=1.58(3)b,Q s (229Ra)=3.09(4)b with an additional scaling uncertainty of ±5%. Furthermore, theJ-dependence of the isotope shift is analyzed in both Ra II transitions connecting the 7s 2 S 1/2 ground state with the first excited doublet 7p 2 P 1/2 and 7p 2 P 3/2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 3 (1986), S. 189-194 
    ISSN: 1434-6079
    Keywords: 36.40 +d ; 35.10.Bg ; 29.20. −c
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We propose to use a Penning trap for spectroscopy of stored cluster ions. A similar device has been built for the purpose of mass measurements of short-lived nuclei produced at the on-line isotope separator ISOLDE/CERN. A resolving power of 500,000 in a mass measurement of39K and an accuracy of 2 × 10−7 for the85Rb/39K mass ratio were obtained. An efficiency for in-flight capture as high as 70% was achieved. The method provides very high sensitivity since typically only 10 to 100 ions are stored in the trap. We intend to perform laser spectroscopy on trapped Na clusters as a first application of the trap technique.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1434-6079
    Keywords: 07.75. + h ; 35.10.Bg
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Doublet mass measurements of the isobars28Si3 and12C7 are performed by use of a Penning trap mass spectrometer and the Fourier transform ion cyclotron resonance (FT-ICR). The carbon and silicon cluster ions are produced by laser ablation. Results of these preliminary measurements are presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...