Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 07.65  (1)
  • 42.79  (1)
Material
Years
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 62 (1996), S. 457-464 
    ISSN: 1432-0649
    Keywords: 42.79
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A commercially available neon indicator lamp in a Relaxation Oscillator (RO) configuration has been demonstrated to be capable of detecting light intensities of the order of nanowatts under ambient light conditions with a subpicometer spectral resolution. The RO has also been shown as capable of acting as a wireless light switch with light intensities of the order of 1 µW. Temporal excitation studies have also shown the predominant mechanism describing the observed frequency changes in the RO to be a result of laser perturbation of the neon lamp when it is in the Townsend-discharge region and not in the abnormal glow.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 46 (1988), S. 209-220 
    ISSN: 1432-0649
    Keywords: 82.80 ; 32.00 ; 07.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Several laser-based methods, namely laser induced fluorescence, laser enhanced ionisation and thermal lensing spectrophotometry are discussed with respect to their capabilities of approaching the extremely high detection sensitivity which is nowadays required in many fields of application, notably in high purity materials, in biomedicine and in the nuclear industry. The discussion is restricted to atomisers operated at atmospheric pressure, i.e., combustion flames, plasmas and graphite furnaces. It is shown that the analytical limit of detection can be in the range of femtograms and that double-resonance excitation possesses significant advantages over single-resonance excitation, both in terms of signal-to-noise ratio and spectral selectivity. In addition, the combination of the fluorescence and ionisation techniques represents a remarkable diagnostic tool. In the nuclear field, the suitability of the technique of thermal lensing for the direct determination and chemical speciation of very low levels of uranium in water is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...