Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Brain tumor ; MRI ; T1 ; T2
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The possibility that cerebral tumours may be graded by measuring T1 or T2 with magnetic resonance (MR) imaging was studied. A consecutive series of patients with subsequently verified gliomas was enrolled, and studied with MR. Patients who had prior surgical, chemotherapeutic or steroid treatment were excluded. Single slice multiple saturation recovery and multiple spin echo techniques were used to measure T1, T2 and proton density in the tumour. In 33 patients with cerebral gliomas there were 5 grade I, 12 grade II, 7 grade III and 9 grade IV. T1 and T2 values tended to be smaller in grade I gliomas than in grades II, III and IV gliomas. Relaxation parameters overlapped considerably in tumours with different grades. Proton density values did not show much change between different grades of gliomas. Relaxation parameters cannot be used to determine tumour grade reliably.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Gradient recalled echo ; MRI ; Sinus occlusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary With T1-weighted gradient recalled echo (GRE) MR images and flow compensation, we studied the superior sagittal sinus in 3 normal volunteers and 3 patients with sinus occlusion. In these images, sites of patency of the superior sagittal sinus were identified due to the high signal intensity of the normal sinus. Tumor invading the sinus was nearly isointense with cerebral gray matter. T1-weighted GRE imaging proves to be an effective technique to evaluate sinus blood flow.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 28 (1986), S. 74-77 
    ISSN: 1432-1920
    Keywords: Head ; MRI ; Image quality
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We studied the subjective rating of MR image quality as field strength, slice thickness, number of acquisitions and matrix size were varied. Matrix and number of acquisitions had the most significant effect on image quality. Therefore, in comparisons of image quality, technique must not be disregarded.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The journal of membrane biology 80 (1984), S. 191-199 
    ISSN: 1432-1424
    Keywords: cardiac sarcoplasmic reticulum ; K+ channel ; ion selectivity ; decamethonium block
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Summary Rabbit cardiac muscle sarcoplasmic reticulum (SR) was isolated and separated into ryanodine-sensitive and-insensitive fractions (L.R. Jones and S.E. Cala,J. Biol. Chem. 256:11809–11818, 1981). Vesicles of cardiac SR were incorporated into planar phospholipid bilayers by fusion and the channel activity of the membrane studied under voltage-clamp conditions (C. Miller,J. Membrane Biol. 40: 1–23, 1978). Both fractions contain a monovalent cation-selective three-state channel. In the presence of 75mm K2SO4, the fully open state (β) conductance of this channel is 157.2±30 pS and the sub-state (α) conductance is 100.7±21 pS. Both open states display the same selectivity sequence for monovalent cations, i.e. K+〉NH 4 + 〉Rb+〉Na+〉Li+ and may be blocked by the skeletal muscle relaxants decamethonium and hexamethonium. Block occurs when the compounds are added to either side of the membrane. The properties of the cardiac SR cation channel are compared with those of the previously reported monovalent cation-selective channels of mammalian and amphibian skeletal muscle SR.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1424
    Keywords: platelet surface membrane ; lipid bilayer ; anion channel ; ion selectivity ; block
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Summary We have investigated the basic properties of a predominantly anion-selective channel derived from highly purified human platelet surface membrane. Single channels have been reconstituted into planar phospholipid bilayers by fusion of membrane vesicles and recorded under voltage-clamp conditions. The channel is found to have the following properties: (i) Channel activity occurs in bursts of openings separated by long closed periods. (ii) The current-voltage relationship is nonlinear. Channel current is seen to rectify, with less current flowing at positive than at negative voltages. Rectification may be due to asymmetric block by HEPES/Tris buffers. In 450mm KCl, 5mm HEPES/Tris, pH 7.2 the single channel conductance at −40 mV is ∼160 pS and at +40 mV is ∼90 pS. (iii) The conductanceconcentration relationship follows a simple saturation curve. Half maximal conductance is achieved at a concentration of ∼1000mm KCl, and the curve saturates at a conductance of ∼500 pS. (iv) Reversal potentials interpreted in terms of the Goldman-Hodgkin-Katz equation indicate a Cl∶K permeability ratio of 4∶1. (v) The channel accepts all of the halides as well as a number of other anions. The following sequence of relative anion permeabilities (in the presence of K+) is obtained: F−〈acetate−〈gluconate−〈Cl−〈Br−〈I−〈NO 3 − 〈SCN−. (vi) Cations as large as TEA+ are permeant. (vii) Current through the channel is blocked in the presence of DIDS, SITS and ATP, but not by Zn2+.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 345 (1993), S. 143-153 
    ISSN: 1434-601X
    Keywords: 21.10.Ma ; 23.20.Lv ; 25.40.Lw ; 27.50.+ e
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Theγ-radiation emitted after thermal neutron capture in isotopically enriched58Ni and60Ni was measured at the ILL high flux reactor by means of Ge/NaI detectors operated in Compton suppression and pair spectrometer mode. The neutron binding energies were determined asB n (59Ni)=8999.15(23) keV and Bn(61Ni)=7820.07(20) keV; some 95% of the totalγ-ray fluxes through59,61Ni were assigned. Theγ-ray strength functions of the primary transitions and the level densities are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 343 (1992), S. 7-14 
    ISSN: 1434-601X
    Keywords: 21.10.Ma ; 23.20.Lv ; 25.40.Lw ; 27.50. + e
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The γ-radiation following single and double neutron capture in isotopically enriched62Ni was studied at the high flux reactor of the Institut Laue-Langevin, using a pair and Compton suppressed germanium detector. Measurements before and after 170 d of breeding were performed. The γ-ray fluxes through63Ni and64Ni are discussed; several new levels and spin-parity assignments were found. On the basis of the known discrete levels and the low-energy neutron resonances, level density parameters were determined within the Constant Temperature Fermi Gas model. The neutron binding energies were measured asB n (63Ni)=6837.92(18) keV andB n (64Ni)=9657.64(24) keV. The63Ni (n, γ) cross section for reactor neutrons was measured to be σ=20 −2 +5 b.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...