Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1434-601X
    Keywords: 23.20.Lv ; 25.70.Gh ; 27.60.+j
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The level scheme of 143 Eu has been extended to I=75/2 in an experiment with the NORDBALL Compton-suppressed Ge detector array and the 110 Pd(37 Cl, 4n) reaction. Most of the scheme shows irregular structure of multiparticle excitations. A strongly populated straight cascade of more than 10 stretched E2 transitions suggests the onset of collectivity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 19 (1980), S. 885-898 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Potentiometric titration curves of oxidized and reduced horse heart cytochrome c in 0.15M KCl at 20°C have been obtained by timed titration (0.125-0.500 μmol/sec) from the isoionic points (pH 10.2-10.4) to pH 3 and back to the isoionic point. Computer-assisted (PROPHET) data acquisition and blank corrections give curves with good precision with a maximum standard deviation of 0.3 groups for an average error of 1%. The potentiometric titration curve of reduced cytochrome c is reversible within the precision of the method and for the pH range studied. The potentiometric curves for oxidized cytochrome c titrated upscale (pH 3-10) and downscale (pH 10-3) are not reversible. However, they show the same ionization behavior after the initial downscale titration. This is probably the result of a conformational change. Comparison of the data herein reported with the titration curves of oxidized cytochrome c already published by others indicates good agreement on the basis of a normalization of the concentration of protein or on the basis of 25 titrable groups between the acid end point and the isoionic pH.Titration of the 2 μmol imidazole in the upscale or downscale direction gives the correct analytical concentration and pK′ after correction for the solvent titration. Titration of reduced cytochrome c in the presence and absence of an additional equivalent of imidazole gave a difference titration curve, which indicates that a group on the protein shifts from pK′ 5.8 to pK′ 5.3 in the presence of imidazole. The pK′ of imidazole, in the presence of the protein, remains at a nearly normal value of 7.34.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...