Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 42.55.Hq  (1)
  • 42.60.By  (1)
Material
Years
Keywords
  • 1
    ISSN: 1432-0649
    Keywords: 42.60.By ; 32.30.Rj
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We report lasing for the first time in nickel on the neon-like J=0→1, 3p→3s transition at 231 Å as well as several weaker transitions including the J=2»1 lines at 298 Å and 304 Å. Amplification is seen only when the prepulse technique of using a low intensity prepulse before the main optical drive pulse is used to illuminate the nickel target. The prepulse technique is also shown to produce lasing in copper and dramatically improve the output of the germanium laser.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0649
    Keywords: 42.55.Hq ; 52.50.Jm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Recent Ne- and Ni-like X-ray laser experiments carried out at the Centre d'Etudes de Limeil-Valenton (CEL-V) are reviewed. A variety of experiments in Ne-like X-ray lasers were performed; here we discuss measurements of soft X-ray amplification in Ge (Z=32) and Sr (Z=38) plasmas. In Ge plasmas produced by 0.53-μm laser light at an irradiance of 6.0×1013 W/cm2, gains between 2.2–2.5 cm−1 on the 232.2 and 236.2 Å J=2−1 lines and a gain of 1.0 cm−1 on the 196.1 Å J=0−1 line were measured. In addition, gains of 4.4 cm−1 and 4.0 cm−1 have been demonstrated on the J=2−1 transitions at 164.1 and 166.5 Å in Nelike Sr at laser intensities of 1.3×1014 W/cm2. The effects of pumping the Ne-like Se X-ray laser with 0.35-μm laser light have also been investigated; the Se lasing spectra is similar to that obtained with 0.53-μm light. Experiments have also been carried out to optimize the gain of the 50.3 Å Ni-like Yb (Z=70) J=0−1 line. For Yb, no significant increase in gain over that previously reported was seen, but the time history of the Ni-like Yb X-ray laser was measured for the first time. Finally, attempts to extrapolate the Ni-like results to shorter wavelength were made using Ta (Z=73), W (Z=74), and Re (Z=75). No definitive observation of the Ni-like J=0−1 lasing lines was made in these experiments.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...