Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 42.80  (1)
  • 82.40 Py  (1)
Material
Years
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 51 (1990), S. 25-30 
    ISSN: 1432-0649
    Keywords: 42.65 Dr ; 82.40 Py
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Recent developments in rotational CARS thermometry and critical issues when comparing vibrational and rotational CARS thermometry are described. In particular, the development of dual broadband rotational CARS and the noise characteristics of this approach are emphasized. The difficulty with unambiguous temperature determination in vibrational CARS with unknown parameters, in particular the nonresonant background susceptibility, and the lower sensitivity of rotational CARS thermometry at flame temperatures are also discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 60 (1995), S. 51-59 
    ISSN: 1432-0649
    Keywords: 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Strategies for spatially resolved soot volume-fraction measurements have been investigated in sooting laboratory flames with known soot characteristics. Two techniques were compared: Laser-Induced Fluorescence in C2 from Laser-Vaporized Soot (LIF(C2)LVS), and Laser-Induced Incandescence of soot (LII). The LII signal is the increased temperature radiation from soot particles which have been heated to temperatures of several thousand degrees as a consequence of absorption of laser radiation. The LIF(C2)LVS technique is based on the production of C2 radicals from laser-vaporized soot which occurs for laser intensities ≥107 W/cm2. A laser wavelength is chosen such that besides vaporizizng the soot, it also excites the C2 radicals, and the subsequent C2 fluorescence signal is detected. The signals from both techniques showed good correlation with soot volume fractions in the studied flame. The dependence of the signals on experimental parameters was studied, and the influence of interfering radiation, such as background flame luminosity and fluorescence from polyaromatic hydrocarbons, on studied signals was established. The potential of the two techniques for imaging of soot volume fractions in laboratory flames was demonstrated. Advantages and disadvantages of the studied techniques are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...