Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 5-HT  (1)
  • Analytical Chemistry and Spectroscopy  (1)
  • Colonoscopy  (1)
  • Evaluation  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 43 (2000), S. S78 
    ISSN: 1530-0358
    Keywords: Screening ; Colorectal cancer ; Immunochemical fecal occult blood test ; Evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: Screening for colorectal cancer using a guaiac-based fecal occult blood, or Hemoccult®, test has been demonstrated to reduce colorectal cancer mortality. However, the magnitude of effectiveness is relatively low because of poor sensitivity of the Hemoccult® test. The immunochemical fecal occult blood test has been shown to be much more sensitive than the Hemoccult® test in detecting preclinical colorectal cancer in an asymptomatic population. The purpose of this article is to discuss the validity of the immunochemical fecal occult blood test and the efficacy of a population-based screening program using the test. METHODS: Relevant articles were primarily identified through MEDLINE search. Review was focused on the studies of population screening programs with the immunochemical fecal occult blood test. RESULTS: Sensitivities for colorectal cancer calculated in the same population were reported to be 67 to 89 percent and only 33 to 37 percent for the immunochemical test and Hemoccult® test, respectively. Case-control studies and other observational studies showed that screening programs using the immunochemical fecal occult blood test by hemagglutination reaction would reduce the risk of dying of colorectal cancer by 60 percent or more for those screened annually compared with those unscreened. It was also shown that a screening strategy using the immunochemical fecal occult blood test had the best cost-effectiveness ratio among the methods available. Nearly 5 million persons are currently screened per year in Japan, yielding 0.15 to 0.2 percent colorectal cancer cases among persons with positive fecal occult blood test results. CONCLUSIONS: These results strongly suggest that a screening program with immunochemical fecal occult blood test has promising advantages in terms of effectiveness over programs with the Hemocult® test. More stress is warranted on introduction of immunochemical fecal occult blood testing as a screening test in place of the guaiac fecal occult blood test.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1530-0358
    Keywords: Graft-vs.-host disease ; Colitis ; Colonoscopy ; Chronic myelogenous leukemia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Endoscopic appearance of the gastrointestinal tract of a patient with severe hemorrhagic enteric graft-vs.-host disease (GVHD) is presented. A 29-year-old man with chronic myelogenous leukemia suffered from severe enteric GVHD after allogeneic bone marrow transplantation. Endoscopy showed hemorrhagic ulceration of the upper jejunum, terminal ileum, and colon at the onset of melena. Sections of biopsies were compatible with acute GVHD. Repeat endoscopy showed gradual healing of the lesions after steroid pulse and antilymphocyte globulin therapy, but the patient died of cytomegalovirus pneumonitis 14 months later. Autopsy revealed submucosal fibrosis of the small intestine and colon.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Naunyn-Schmiedeberg's archives of pharmacology 344 (1991), S. 564-567 
    ISSN: 1432-1912
    Keywords: Vomiting ; 5-HT ; 2-Me-5-HT ; 5-HT3 Receptor antagonism ; Cancer Chemotherapy ; House musk shrew (Suncus murinus)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The emetic effects of 5-hydroxytryptamine (5-HT) and 5-HT3 receptor agonists were investigated in the house musk shrew, Suncus murinus. 5-Hydroxytryptamine (5-HT; i.p., i.v., s.c.) and 2-methyl-5-HT (2-Me-5HT; i.p.) but not 5-hydroxyindoleacetic acid (i.p.) or 5-ethoxytryptamine (i.p.) induced emesis with very short latency. Tropisetron (ICS 205-930, a 5-HT3 receptor antagonist, s.c.) blocked the emesis induced by 5-HT (10 mg/kg, i.p.) and 2-Me-5-HT (5 mg/kg, i.p.) with respective ID50 values of 7.8 and 70.9 μg/kg. Pindolol (5-HT1 receptor antagonist) and ketanserin (5-HT2 receptor antagonist) were about 100 times less potent than tropisetron. The emesis induced by 5-HT was prevented by surgical vagotomy but not by pretreatment with a combination of atropine (0.1 mg/kg, s.c.) and hexamethonium (10 mg/kg, s.c.). These results clearly indicate that 5-HT is emetogenic probably through a stimulation of peripheral 5-HT3 receptors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 24 (1993), S. 191-197 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The 1025 cm-1 band which occurs in the SERS of pyridine and halide anion was investigated in detail on a silver electrode in neutral and acidic solution. The 1025 cm-1 band was observed to increase in intensity when the silver electrode was treated with the ORC procedure in the presence of pyridine and halide and the concentration of pyridine was then diluted in neutral solution. On the other hand a band began to appear strongly at 1025 cm-1 when the solution was acidified with HCl after the ORC. It was confirmed that the 1025 cm-1 band appearing on dilution in neutral solution has by the same origin as the 1025 cm-1 band which appeared on acidification. The behaviour of the band can be understood if it is assumed that the species giving rise to the 1025 cm-1 band is a silver-pyridine-halide complex generated by the electrode reaction during the ORC.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗