Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-6903
    Keywords: Behavior ; serotonin ; DOI ; 8-OH-DPAT ; 5-HTP ; depression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Studies from this laboratory have demonstrated that administration of the selective 5-HT2/1C antagonist LY53857 can block 5-HTP-induced response suppression. To further investigate the serotonergic mechanisms involved in this effect, we decided to test the capacity of LY53857 to block response suppression induced with two selective 5-HT agonists. After a 15 minute baseline period, rats trained to press a lever for milk reinforcement on a VI 1′ schedule were given IP injections of 1.0 mg/kg DOI, or 1.0 mg/kg 8-OH-DPAT to induce response suppression. Subsequently, rats were injected with 1.0 mg/kg LY53857 1 hour prior to DOI- or 8-OH-DPAT-induced response suppression. Preinjections with LY53857 resulted in a 100% blockade of DOI-induced response suppression whereas the same dose did not block response suppression induced with 8-OH-DPAT. These results indicate that the 5-HTP-induced response suppression shows some pharmacological similarity to DOI-induced response suppression and may be mediated through 5-HT2 and/or 5-HT1C receptors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 9 (1988), S. 325-350 
    ISSN: 1572-9559
    Keywords: Array receiver ; quasi-optics ; indium antimonide mixers
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We describe an experimental array receiver intended for radioastronomical observations of the J=3→2 line of carbon monoxide. It consists of six indium antimonide mixers cooled to ∼2K in a pumped helium cryostat, with rectangular feed horns arranged on a 3×2 grid at the f/9 focus of the UK Infrared Telescope (UKIRT). Each detector is mounted in a length of fundamental mode waveguide and has an independently tunable backshort. Local oscillator power is provided by a frequency tripler pumped by a klystron, and is coupled to the array via a “lossless” quasi-optical coupler which is described in detail. The beam patterns and performance of the coupler have been measured and are in good agreement with theory.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...