Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 25 (1981), S. 119-125 
    ISSN: 1432-0630
    Keywords: 72.40 ; 85.30 ; 85.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract An infinite stack ofp—n junctions with smoothly varying bandgap from ∞ to 0 is considered. AnI —V characteristic is derived, which is more correct than the classical exponential characteristic. It is shown that open-circuit operation is a reversible process and leads to the Carnot efficiency, if one defines the efficiency in the way that is usual in the theory of thermodynamic engines. If instead one uses the definition of efficiency usual in photovoltaics, open-circuit mode gives rise to zero efficiency. Then operation at maximum efficiency equals operation at maximum power and is not reversible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 17 (1979), S. 623-628 
    ISSN: 1741-0444
    Keywords: Arterial system ; Diastolic pressure decay ; Frequency-response vector diagram ; Input impedance ; Total arterial compliance ; Windkessel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The total arterial compliance of the arterial system was computed from its input impedance by expressing the impedance in terms of its frequency-response vector diagram (f.r.v.) The f.r.v. plot of a 3-element windkessel subjected to random pacing follows, theoretically, a circular path. Since the windkessel model serves as a good approximation for the arterial system, we have used the simple properties of its f.r.v. plot to obtain the compliance, which is otherwise normally determined from the peripheral resistance and the time constant of the diastolic pressure decay. The arterial compliance can also be determined from the impulse response function of the arterial system. Data obtained from dog experiments during no intervention, aortic occlusion and during occlusion of both carotid arteries have been analysed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...