  • 1
    ISSN: 1619-7089
    Keywords: Contraction fraction ; 99mTc-MIBI ; SPECT ; Myocardial size ; Radionuclide ventriculography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Criteria for the detection of coronary artery disease in nuclear cardiology include visualization of perfusion defects and functional impairment of contraction. The purpose of this study is to combine both methods in one procedure with the new myocardial perfusion tracer, 99mTc-methoxy-isobutyl-isonitril (MIBI), reducing time and radiation burden to the patient. Following an uncomplicated recovery, ten patients with first myocardial infarction participated in this study. Radionuclide ventriculography (RNV) was performed at rest and during exercise. Within 2–3 days, 370 MBq 99mTc-MIBI were injected and SPECT acquisition commenced 1 h later. Data processing included a scar image in polar coordinates. Areas of significantly reduced tracer uptake were expressed as a percentage of the total myocardial area. Directly following SPECT, resting and maximum exercise gated planar LAO images were recorded and the contraction was quantified. The concept of the contraction fraction (CF) rested on the end systolic change in count distribution: their increase in density and their centripetal concentration. For comparison, geometrical inner edge detection techniques were also applied. All algorithms for describing an EF equivalent were verified by computer simulations, showing a perfect correlation over a wide range of preset EFs. When applied to the patient studies only the non geometric methods revealed a good correlation with the ejection fraction (EF) obtained by RNV, and with the infarct size measured by SPECT. The corresponding correlation coefficients (r), standard errors (SEE) and the regression lines read as follows (in %): CF=0.56×EF+24.8; r=0.87; SEE=4.98; CF=-0.53×SPECT+71.5; r=0.93; SEE=4.19. Thus, estimation of the left ventricular function by the above defined CF is feasible, easy to perform and clinically meaningful. In one procedure with 99mTc-labelled MIBI not only the perfusion abnormalities were detectable, but also any reduction in function by a valied EF equivalent. Although the monochromatic gamma spectrum of the radionuclide provided better tissue penetrating power, the inner edge of the left ventricle was poorly outlined (especially in the stress studies) and does not lend itself to clinical routine practice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 13 (1987), S. 439-442 
    ISSN: 1619-7089
    Keywords: Emission tomography ; Image distortion ; Gamma camera
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Image quality in single photon emission computed tomography (SPECT) using a rotating gamma camera is dependent on the time course of the tracer in the field of view. If acquisition times are slow comapred to the tracer turnover, artifacts may occur in the reconstructed images. The properties of such artifacts were studied by computer simulation. Experimental projection data of point sources, cylindrical phantoms, and an anatomically realistic brain phantom were altered by sequentially weighting the projections with a function that varied exponentially or linearly with time. The observed distortion in the reconstructed images could be related to the ratio between the object activity variation and the camera rotation time. If the tracer concentration changed less than a factor of two during one camera rotation then little image distortion was visible although quantitatively the resolution was degraded. If the object's activity variation with time is fast enough to produce noticeable distortion, the artifacts can be reduced by performing multiple, rapid, camera rotations, instead of one rotation, for the same total acquisition time. The proposed procedure is computer storage space intensive and takes longer to produce the transaxial images, but improves image quality.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...