ISSN:
1432-0509
Keywords:
Computed tomography, technique
;
Liver volume, measurement
;
Abdomen, helical CT
Source:
Springer Online Journal Archives 1860-2000
Topics:
Medicine
Notes:
Abstract Background: Accurate noninvasive measurement of the volume of the liver has many potential clinical applications and is an important element in the preoperative evaluation of the liver transplant recipient. Helical (or spiral) computed tomography (CT) has theoretical advantages over conventional CT in this application because the entire liver can be imaged in a single breath-hold, limiting inaccuracies related to patient motion and respiratory variation. Methods: We compared liver volumes measured by conventional CT and helical CT in 22 patients undergoing preoperative evaluation for liver transplantation. Results: The mean volume for helical CT is 1328 ml (SD 405) and conventional CT is 1323 ml (SD 417). Conclusions: We found no significant difference between the helical CT and conventional CT volumes for each patient.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF00200395
Permalink