Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric surgery international 7 (1992), S. 149-151 
    ISSN: 1437-9813
    Keywords: Midgut non-rotation ; Right paraduodenal hernia ; Abscessed hernia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A 3-year-old boy with a history of recurrent episodes of abdominal pain and vomiting, a prior history of intra-abdominal sepsis (amoebiasis), and marked retroperitoneal mesenteric lymphadenopathy on ultrasound was admitted to the hospital because of severe abdominal pain of 2 days' duration associated with fever, nausea, and vomiting. His abdomen was distended and tender and a plain X-ray film revealed a large, dumb-bell-shaped double bubble in the mid-upper abdomen. A barium enema showed non-rotation of the colon with the cecum in the left upper quadrant. At operation, a large, dumbbell-shaped right paraduodenal hernia filled with air and pus was found, but no intestine. The body of the duodenum crossed the hernia and gave it its dumb-bell shape. The hernia/abscess was opened and drained. Penrose drains were left in the abscessed area and the margin of the hernia sac that contained the superior mesenteric artery was closed around the drains with care. The postoperative course was uneventful with no recurrence of symptoms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 21 (1993), S. 97-106 
    ISSN: 1573-9686
    Keywords: Cardiovascular modeling ; Blood flow in vessels ; Navier-Stokes equations ; Nonlinear flow ; Vessel taper and compliance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract A popular and useful technique used to model blood flow in cardiovascular simulations is to divide each blood vessel into a series of segments, each with its own lumped resistance, intertance, and compliance parameters. The values of these parameters are usually obtained through a simplification of the Navier-Stokes equations for fluid flow. However, the simplification often ignores the nonlinear and convective terms of the equations, resulting in errors in the parameter values, especially in the value found for resistance per unit length. We report a new method for the calculation of vessel resistance per unit length which takes into account the effects of vessel taper and wall compliance. It is shown that these effects can be addressed by the addition of two time-varying terms to the calculation of resistance per unit length. One term, due to vessel taper, is proportional to volumetric flow rateQ. The other term, due to vessel compliance, is proportional to ∂p/∂t. These variables are readily available in computer simulations of blood flow in lumped parameter systems. Using data for the descending aorta, the new parameter values, when averaged over a cardiac cycle, compare favorably with results in the literature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Unknown
    Champaign, Ill : Project Gutenberg
    Keywords: Folk songs, Irish, Texts. ; Songs with piano.
    ISBN: 0-585-00944-9
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Unknown
    Champaign, Ill : Project Gutenberg
    Keywords: Folk songs, Irish, Texts.
    ISBN: 0-585-00945-7
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...