    ISSN: 1439-6327
    Keywords: Acceleration ; Eccentric ; Concentric ; Isokinetic ; Method error
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A new computerized dynamometer (the SPARK System) is described. The system can measure concentric and eccentric muscle strength (torque) during linear or nonlinear acceleration or deceleration, isokinetic movements up to 400° · s−1, and isometric torque. Studies were performed to assess: I. validity and reproducibility of torque measurements; II. control of lever arm position; III. control of different velocity patterns; IV. control of velocity during subject testing; and, V. intra-individual reproducibility. No significant difference was found between torque values computed by the system and known torque values (p〉0.05). No difference was present between programmed and external measurement of the lever arm position. Accelerating, decelerating and isokinetic velocity patterns were highly reproducible, with differences in elapsed time among 10 trials being never greater than 0.001 s. Velocity during concentric and eccentric isokinetic quadriceps contractions at 30° · s−1, 120° · s−1 and 270° · s−1 never varied by more than 3° · s−1 among subjects (N=21). Over three days of testing, the overall error for concentric and eccentric quadriceps contraction peak torque values for 5 angular velocities between 30° · s−1 and 270° · s−1 ranged from 5.8% to 9.0% and 5.8% to 9.6% respectively (N=25). The results indicate that the SPARK System provides valid and reproducible torque measurements and strict control of velocity. In addition, the intra-individual error is in accordance with those reported for other similar devices.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 52 (1984), S. 266-271 
    ISSN: 1439-6327
    Keywords: Human ; Endurance exercise ; Muscles ; Fibre types ; Histocytochemistry ; Ultrastructure ; Morphometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The main fibre types ofM. vastus lateralis of 10 trained or untrained male individuals (25–35 years) were quantitatively determined by morphological techniques; the fibre types being defined according to the M-band appearance. The volume density of mitochondria (Vmit) was higher in endurance-trained muscles.Vmit was higher in Type 1 than in Type 2 fibres, there being no difference between subtypes of Type 2 fibres. The volume density of lipid droplets (Vli) showed a wide range of values both with respect to degree of training and between fibre types. Z-band width was not influenced by endurance training, but was considerably larger in Type 1 than in Type 2 fibres. Discriminant analysis showed that 46% of the fibres, preclassified according to the M-band appearance, would have been correctly allocated on basis of theVmit. The corresponding value for lipid droplets was 42% and for the Z-band width, 62%. It is concluded thatVmit is not a satisfactory criterion for discriminating between fibre types, especially between Type 2A and Type 2B in trained subjects. The study also shows that endurance training reduces the relative importance of individual-dependent factors in comparison with muscle fibre properties when concerningVmit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...