Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Acute respiratory failure  (1)
  • Anorectal manometry  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 40 (1997), S. 1328-1335 
    ISSN: 1530-0358
    Keywords: Systemic sclerosis ; Anorectal manometry ; Fecal incontinence ; Rectoanal inhibitory reflex ; Esophageal manometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: This study was designed to compare esophageal and anorectal function parameters in patients with systemic sclerosis and to define the role of anorectal manometry in the diagnosis of gastrointestinal involvement of systemic sclerosis. PATIENTS AND METHODS: Twenty-six consecutive patients (22 females) with systemic sclerosis originally referred for assessment of esophageal function were evaluated by esophageal and anorectal manometry. Anorectal function parameters were compared between patients with normal and those with disturbed esophageal function. RESULTS: A total of 17 of 26 patients (65 percent) had severe esophageal dysfunction with aperistalsis of the lower two-thirds of the esophagus, whereas 9 patients (35 percent) had normal esophageal manometry. Only three patients (11.5 percent) suffered from occasional fecal incontinence. Anorectal function parameters (resting pressure, maximum squeeze pressure, perception threshold) were not significantly different between patients with normal and those with disturbed esophageal motility. Rectoanal inhibitory reflex was excitable in nearly 90 percent of patients. CONCLUSION: In an unselected group of patients with systemic sclerosis, fecal incontinence and abnormal anorectal function are rather rare findings. Anorectal manometry cannot differentiate between patients with and without gastrointestinal involvement of systemic sclerosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Transthoracic electrical impedance ; Acute respiratory failure ; Pulmonary interstitial edema ; Intrathoracic fluid volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The alteration (ΔZ 0 ) of transthoracic electrical impedance (TEI) during extracorporeal hemodialysis (EHD) was investigated in two Groups of patients with acute renal and acute respiratory failure, that differed with respect to the severity of respiratory insufficiency. Group I had moderate respiratory failure (Fi O 2 0.31±0.10, Pa 0 2 84±14 mmHg), and Group II had severe respiratory failure (Fi 0 2 0.75±0.17, Pa O O 77±14 mmHg). There was a significant correlation between increase in TEI (ΔZ0) and decrease in body weight (ΔBW) in each individual patient, but the slope of regression lines was remarkably flattened in Group II. In Group I, ΔTEI was 1.9±0.9 Ω, the calculated TEI for 500 gr decrease in BW (ΔZ0–500 gr) was 0.59±0.21 Ω, and a significant correlation existed between pooled data of ΔZ0 and ΔBW. In Group II TEI increased less significantly, ΔTEI was 0.6±0.3 Ω (P〈0.001), ΔZ0–500 gr was 0.26±0.27 Ω (P〈0.01), and there was no correlation between pooled data of ΔZ0 and ΔBW. Increase of TEI in Group II could be completely attributed to increase in hematocrit. It is concluded that patients of Group I with acute renal failure and moderate respiratory failure lost intrathoracic fluid during EHD, whereas patients of Group II with severe respiratory failure did not. TEI during EHD may serve as a test for detection of fixed fluid within the pulmonary interstitium indicating a poor prognosis of the acute respiratory failure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...