Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 5 (1995), S. 176-180 
    ISSN: 1432-1084
    Keywords: Adverse reaction ; Contrast media ; Kidney ; Nephrotoxicity ; Urography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A small but significant proportion of patients given X-ray contrast agents subsequently experience a decline in renal function. Experimental studies in rats aimed at identifying the mechanism of renal effects show vacuolation of proximal convoluted tubules. This report documents that such vacuoles normally have a proteinaceous content and that14C-radiolabelled contrast agent (iodixanol) is specifically localised within the vacuolated tubules 24 h after administration. On the basis of the persistence of some large droplets in proximal tubules, a small percentage of the administered dose of X-ray contrast agent appears to be trapped intracellularly within large proteinaceous droplets (the vacuoles) and slowly released over several weeks. Enzyme histochemistry identifies contrast-medium-induced droplets as an abnormal population of lysosomes. We propose that in the absence of pre-existing renal impairment, this slowly reversing lysosomal abnormality of proximal tubules is within the kidney's functional reserve capacity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 5 (1995), S. 176-180 
    ISSN: 1432-1084
    Keywords: Adverse reaction ; Contrast media ; Kidney ; Nephrotoxicity ; Urography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A small but significant proportion of patients given X-ray contrast agents subsequently experience a decline in renal function. Experimental studies in rats aimed at identifying the mechanism of renal effects show vacuolation of proximal convoluted tubules. This report documents that such vacuoles normally have a proteinaceous content and that 14C-radiolabelled contrast agent (iodixanol) is specifically localised within the vacuolated tubules 24 h after administration. On the basis of the persistence of some large droplets in proximal tubules, a small percentage of the administered dose of X-ray contrast agent appears to be trapped intracellularly within large proteinaceous droplets (the vacuoles) and slowly released over several weeks. Enzyme histochemistry identifies contrast-medium-induced droplets as an abnormal population of lysosomes. We propose that in the absence of pre-existing renal impairment, this slowly reversing lysosomal abnormality of proximal tubules is within the kidney's functional reserve capacity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 25 (1997), S. 777-787 
    ISSN: 0142-2421
    Keywords: XPS ; x-ray photoelectron spectroscopy ; energy calibration ; peak location ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: An analysis is presented of issues involved in peak location for the calibration of the binding energy (BE) scales of x-ray photoelectron spectrometers. These issues include the effects of peak asymmetry, the surface core-level shift, and the avoidance of a sloping background when fitting spectra for energy calibration purposes. Examples of uncertainty budgets for BE measurements are then presented in which illustrative values are shown for the repeatability standard deviation (for repeated BE measurements of the same calibration peak), the expanded uncertainty (at the 95% confidence level) for BE measurements following calibrations based on different numbers of peak measurements, and the tolerance for BE-scale drift and non-linearity for two chosen values (±0.1 and ±0.2 eV) of the total expanded uncertainty for a BE measurement (at the 95% confidence level). It is recommended that a user prepare an uncertainty budget of this type to show clearly the sources of random and systematic error in BE measurements following a calibration.The reference data published by the UK National Physical Laboratory for BE-scale calibration were obtained from fits with a quadratic function to a group of points comprising the top 5% of each peak. Most commercial x-ray photoelectron spectrometers have software available for spectrum synthesis, and we consider here the use of the commonly available Lorentzian, Gaussian, and asymmetric Gaussian functions for peak location. Illustrative fits with Cu 2p3/2 spectra (measured with unmonochromated Al x-rays) showed that comparable accuracy and precision could be obtained with Lorentzian and Gaussian functions as with the quadratic-equation method when different fractions of the peak were fitted. For this asymmetrical line, the asymmetric Gaussian function allowed better accuracy and precision to be obtained with a greater fraction of the line than was possible with the symmetrical functions. © 1997 by John Wiley & Sons, Ltd.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...