Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/Bioenergetics 1099 (1992), S. 271-274 
    ISSN: 0005-2728
    Keywords: Bacteriochlorophyll c ; Chlorosome ; Green photosynthetic bacterium ; Light-harvesting antenna ; Linear dichroism ; Pigment aggregate
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0304-4173
    Keywords: Bacteriochlorophyll c ; Chlorosome ; Green photosynthetic bacterium ; Light-harvesting antenna ; Linear dichroism ; Pigment aggregate
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0428
    Keywords: Affinity chromatography ; anion exchange chromatography ; fructosamine ; haemoglobin A1c ; glycaemic control ; glycated protein
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A method for determination of serum glycated albumin by high-performance liquid chromatography is presented. The system involves anion exchange chromatography to separate albumin and consecutive boronate affinity chromatography to separate glycated and nonglycated albumin. The method is rapid (20 min), precise (coefficient of variation, 0.7–4.9%), requires only a small sample (5 μl), and can be automated. Assay of glycated albumin by this method is not influenced by the protein concentration of the sample or the presence of glucose. The variation in glycated albumin values in consecutive samples obtained within a day from diabetic patients (coefficient of variation, 2.02±0.65%) was significantly smaller (p〈0.001) than that of values for fructosamine (coefficient of variation, 4.33±2.0%). The values of glycated albumin in normal subjects (20.2±1.6%) were clearly less than those in diabetic patients [39,6±5.4% in 40 Type 1 (insulin-dependent) and 39.4±5.9% in 25 Type 2 (non-insulin-dependent) patients]. The serum glycated albumin level was well correlated with HbA1c in 65 diabetic patients (r=0.60). Because the life span of albumin in the circulation is short, measurement of glycated albumin should be useful as a short-term index of glycaemic control.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 28 (1990), S. 317-324 
    ISSN: 1741-0444
    Keywords: Automatic calibration ; Eye movement ; Infra-red light ; Line-of-sight displacement ; Photoelectric limb tracking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An eye pointer was developed as a new line-of-sight displacement analyser. It analyses an observer's eye movements and superimposes their line of vision on a TV image which is the same as their view. A newly developed miniature colour field camera and very compact eye-movement sensors are attached to a translucent reinforced plastic goggle affording a wide view and excellent safety. A small case is provided for the eye-movement detecting circuit and the camera controller unit etc. Its weight is only 1·2 kg and one can easily participate in sports activities while wearing it. Eye-movement data are transmitted with the VHF video signal. The receiver, which analyses the eye movements and processes the TV image, is also compact and easy to carry. The calibration is automatic and completed within 1 min with a high degree of accuracy. By showing the tennis player's line of vision as an example, we were able to obtain good results with application in broadcasting programmes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...