Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 459-463 
    ISSN: 0935-6304
    Keywords: LC-GC ; Aqueous samples ; Large volume injection ; PTV injector ; Solid-phase extraction ; Thermal desorption ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A system is described that allows the introduction of large volumes of water samples in capillary GC. Water elimination is carried out in the solvent split mode in a PTV injector with a packed liner. Two ways of separating water and analytes, i.e. evaporative and non-evaporative (solid-phase extraction), are compared. Sampling in the solid-phase extraction mode is favorable both in terms of recovery as well as with regard to sampling time. Quantitative recovery is obtained for priority pollutants ranging in volatility from dimethyl-phenol to phenanthrene. Losses occur for more volatile compounds, but even for these compounds the repeatability of the recoveries remains acceptable. With the system described here, water samples up to at least 1 ml of water can be directly analyzed. The detection limits are in the sub-ppb range.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 20 (1997), S. 385-393 
    ISSN: 0935-6304
    Keywords: Sorptive preconcentration ; Thermal desorption ; Air enrichment ; Environmental samples ; Natural gas ; PAHs ; Nitro-PAHs ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for the preconcentration of trace components from gaseous samples is described. The system is based on enrichment of the solutes on a packed bed of 100% polydimethylsiloxane (PDMS) particles followed by thermal desorption and GC analysis. It was demonstrated that breakthrough volumes for packed PDMS traps can be calculated from theoretical equations. The PDMS material exhibits excellent thermal stability even after 200 consecutive runs. Additional advantages of packed sorbent beds over conventional adsorbent materials include high inertness, the absence of displacement effects and a reduced affinity for water. The practicality of the system was demonstrated by the analysis of air and natural gas using the system described here, components in the range of octane to benso[a] pyrene could be quantitatively trapped and thermally desorbed at mild temperatures. With the present set-up the detection limit is in the order of 0.1 ng/m3 (MSD detector).
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource