Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Clinica Chimica Acta 224 (1994), S. 203-207 
    ISSN: 0009-8981
    Keywords: Aortocoronary bypass surgery ; Creatine kinase isoenzyme MB ; Mass concentration ; Myocardial infarction
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 19 (1993), S. 343-346 
    ISSN: 1432-1238
    Keywords: Noise ; Alarms ; ICU
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective The growing number of technical devices in ICUs makes noise exposure a major stressor. The purpose of this study was to assess noise levels during routine operation in our ICU. Design Our ICU is an open ward with four rooms, constructed in the 1960s. During the study period, 4 patients were in the controlled room and were treated by 4 nurses during the day and by 2 at night. A-weighted sound pressure levels (SPL) were measured continuously for 2 days and nights. Also measured were the alarms of various appliances. For gross overall evaluation it is customary to state the Leq, i.e. the energy-averaged level during measurement. The annoyance caused by noise depends more on rare events of high intensity. Therefore, the distribution of SPL values (Ln) over time was also analysed. Results SPL was roughly the same during the day and at night, with Leq between 60–65 dB(A) and peaks up to 96 dB(A). Most alarms reach an SPL of 60–70 dB(A), but some exceed 80 dB(A). During teaching rounds Leq exceeds 65 dB(A). Conclusion During the day and at night SPL always surpasses the permissible noise exposure for 24 h of 45 db(A) recommended by the US Environmental Protection Agency. Alarms cause the most irritating noise. Hospital management should pay attention to internal noise, and SPL should be measured routinely.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...