Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 226 (1978), S. 55-59 
    ISSN: 1432-0711
    Keywords: Gewebe-pH-Messung ; Patienten-Überwachung ; Allgemeinnarkose ; Tissue pH measurement ; Patient monitoring ; General anesthesia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary 43 patients under general anesthesia were monitored by continuous tissue pH measurement and intermittend micro-blood-samples. The values obtained for the capillary pH and tissue pH were correlated. A highly significant correlation was found between tissular pH and capillary pH. Different methods of general anesthesia apparently do not influence the continuous tissue pH measurement.
    Notes: Zusammenfassung 43 Patienten in Allgemeinnarkose wurden durch kontinuierliche Gewebe-pH-Messung und intermittierende kapilläre pH-Bestimmung überprüft. Die gewonnenen Gewebe-pH-Werte wurden mit den entsprechenden kapillären pH-Werten korreliert. Es konnte eine hochsignifikante Korrelation zwischen den beiden Werten gefunden werden. Offenbar beeinflussen verschiedenartige Narkosearten die kontinuierliche pH-Meßmethode nicht.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 226 (1978), S. 129-132 
    ISSN: 1432-0711
    Keywords: pH-Wert-Messung ; Fetaler Säure-Basen-Status ; Gewebe-pH-Wert ; pH-Wert-Elektrode ; pH-Measurement ; Fetal acid-base status ; Tissue-pH ; pH-Electrode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Tissue pH values of 70 fetuses have been measured continuously during labor using the micro-electrode designed by Stamm. Significant correlations between continuous tissue pH and corresponding micro blood values can be shown. However, the relationship between patterns of tissue pH and capillary pH values seems not to be very constant. Therefore, the reliability of individual tissue pH measurements is still questionable.
    Notes: Zusammenfassung Bei 70 Feten wurde während der Geburt mit der von Stamm entwickelten Mikroelektrode der pH-Wert kontinuierlich registriert. Zwischen den Werten der kontinuierlichen pH-Registrierung und den entsprechenden Mikroblutwerten können signifikante Korrelationen aufgezeigt werden. Das Verhalten der beiden Werte (Gewebe-pH/kapilläres pH) ist bei Veränderungen im Säure-Basen-Haushalt jedoch nicht konstant. Deshalb ist die Zuverlässigkeit und die Aussagekraft der kontinuierlichen pH-Messung für den Einzelfall noch fraglich.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...