Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (3)
  • Antarctica  (1)
  • Mid-Ocean Ridge  (1)
  • 1
    ISSN: 1573-0581
    Keywords: East Pacific Rise ; multibeam sonar surveying ; Mid-Ocean Ridge ; magmatic plumbing system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract Detailed bathymetric data from a Hydrosweep multibeam sonar survey of a 250 km-long portion of the ‘superfast’-spreading southern East Pacific Rise crest and flanks show that the along-axis variation in morphology and axial depth differs significantly from that observed at the fast-spreading northern East Pacific Rise. While the deep mantle upwelling pattern is similar under the northern and southern East Pacific Rise, our observations require that the connectivity of the shallow, subcrestal plumbing system be more efficient beneath the ‘super-fast’ spreading southern East Pacific Rise than beneath the slower spreading northern East Pacific Rise.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-2932
    Keywords: 234Th ; particle flux ; Ross Sea ; Antarctica ; organic C, N, Si ; scavenging rates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The distribution of dissolved and particulate234Th in the upper 200 m of the water column was obtained for three stations in the Ross Sea off Victoria Land and Terra Nova Bay. At site 24a, close to the retreating ice margin, all the sampled depths showed deficiencies in234Th relative to the equilibrium with238U. These are related to uptake of234Th onto sinking particles. Residence times of234Th in solution and of particulate234Th were 130–247 days and 8.1–6.6 days, respectively. A high particle flux (1.23–5.03 g m−2 d−1) was calculated at this station. At the other two sites (11c and 15c),234Th depth profiles are irregular, probably due to the release of dissolved234Th by decomposing particles at certain depths, or to the contribution from lateral advection. Bulk mass fluxes measured by floating traps at stations 11c and 15c are very low (66–138 mg m−2 d−1). Also fluxes of organic carbon and nitrogen, and biogenic silica are reported for these two sites. The calculated fluxes are discussed with respect to methodologies and to the dynamics of the ice margin retreat.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 573-575 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Cryogenic cooling ; Volatile aromatics ; Water removal ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 663-665 
    ISSN: 0935-6304
    Keywords: Purge/GC ; Cryogenic cooling ; Vinyl chloride ; Purgeable gases ; Nafion ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 869-873 
    ISSN: 0935-6304
    Keywords: Capillary chromatography ; Purge GC ; Volatile organic chemicals ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A gas chromatographic method for volatile organic chemicals in which an aqueous sample is purged directly to a cryogenically cooled, fused silica column uses a Nafion tube drier between the purge vessel and GC column. The Nafion strips water from the gas stream during the purge step while allowing volatile halocarbons and aromatics to continue to the GC column. Examples of this technique are presented on 0.53 mm and 0.25 mm fused silica columns coated with a variety of stationary phases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...