Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0584
    Keywords: Key words Aspirin ; Bleeding time platelets ; von Willebrand factor ; Essential thrombocythemia ; Bleeding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Patients with essential thrombocythemia (ET), who frequently have bleeding complications, may manifest an excessive prolongation of the bleeding time (BT) after ingestion of aspirin (ASA). The reason for this excessive prolongation of the BT is unknown, but it is attributed to qualitative platelet defects. Since patients with ET may also have acquired abnormalities of plasma and platelet von Willebrand factor (vWF), we questioned whether the excessive prolongation of the BT by ASA was related to changes in either plasma or platelet vWF. To that end, we studied BT and plasma and platelet vWF in ten ET patients, ten patients with reactive thrombocytosis (RT), and ten normal individuals, both before and after administration of 500 mg ASA for 7 days. In a second study, the effect of DDAVP infusion on plasma vWF in relation to the BT was studied in ten normal individuals and ten ET patients after treatment with 100 mg ASA for 3 days. In the first study, treatment with ASA resulted in a significant prolongation of the BT in normal subjects, RT patients, and ET patients. However, in five ET patients an excessive (〉2 SD) prolongation of the BT by ASA was observed. Although ASA induced no direct changes in either plasma or platelet vWF levels in either normal subjects, RT patients, or ET patients, all five ET patients who showed an excessive prolongation of the BT by ASA had significantly decreased levels of large vWF multimers in plasma. In the second study, infusion with DDAVP resulted in a significant increase in plasma large vWF multimers, paralleled by a normalization of (excessively) prolonged BT. Our data suggest that in ET inhibition of platelet function by ASA in the presence of concurrently decreased levels of large vWF multimers in plasma may have provoked the excessive BT prolongation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 263-270 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A publically distributed data base of evaluated electron ionization mass spectra is formed by selecting certain mass spectra from a much larger archive collection. The selection process is automated and a single spectrum for each substance is selected from multiple spectra of the same substance with the aid of a quality index (QI). The quality index is evaluated for efficacy in selecting the best spectrum, some modifications of the QI definition are made, and the redefined QI is used to select a new data base.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A liquid-solid extraction method suitable for rapid screening of sulfonated azo dyes in municipal wastewater has been developed. The dyes (Color Index Acid Yellow 23, Red 14 and Yellow 49) were separated on a short, reversedphase liquid chromatographic column with a water-methanol gradient containing 2 mM sulfuric acid. The column effluent was directed via a split-valve to an ion spray liquid chromatography/mass spectrometry (LC/MS) interface to an atmospheric pressure ionization mass spectrometer. The ion spray LC/MS system produced abundant [M - Na]- and [M - 2Na]2- ions according to the number of sulfonic acid substituents. Collision-induced dissociation of the parent ions for the dyes studied gave the SO3-. fragment common to sulfonated compounds plus additional daughter ion fragments characteristic of each dye. The dyes were quantified by monitoring from four to six different daughter ions of each dye. The relative abundances and the sum of the daughter ion current counts were used for confirmation and quantification with external standards. Recoveries of the dyes were in the range of 70-122%, and the relative standard deviation of replicate determinations was 5.4-12%. The method detection limit was three times higher for Acid Yellow 23 compared with the other two dyes, which could be detected down to 50 ppb in municipal wastewater.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 1 (1974), S. 427-428 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 547-552 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Over 1400 electron ionization mass spectra of selected organic compounds have been measured under carefully defined conditions. In this paper, the variables such as sample purity and spectrometer calibration that are controlled are described. The quality of the resulting spectra as well as the cost of the measurements is reported.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Data are presented on the limits of detection for a series of nine compounds in negative chemical ionization (NCI) mass spectra obtained in five different mass spectrometers: Finnigan 4000 with a 4500 ion source, Kratos MS-80, Hewlett-Packard 5985 and two Finnigan 4500s. The nine compounds undergo either resonance capture or dissociative capture of an electron at optimum energies ranging from 0.0 to 1.1 eV. The limits of detection generally increased with increasing optimum electron energy. The limit of detection as a function of optimum electron capture energy is expected to provide information about the electron energy distribution in the ion sources. The data showed scatter within and between instruments. The scatter is believed to be due primarily to reactions with low levels of adventitious gases such as oxygen in the ion source. The data also suggested wide variations in electron energies between the instruments. The variation in the electron energy distribution is thought to have been caused by variations in the ion optical fields within the instruments. These results suggest that the requirements for reproducibility in NCI mass spectra at the limit of detection are rigorous control of trace gases in the ion source, control of the electric fields within the source including ion optical fields that penetrate the source aperture control of pressure, temperature and other factors that influence NCI mass spectra.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...