Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemical Engineering  (22)
  • Analytical Chemistry and Spectroscopy  (21)
  • Constipation  (5)
  • 1
    ISSN: 1530-0358
    Keywords: Biofeedback ; Constipation ; Anismus ; Pelvic outlet obstruction ; Paradoxical puborectalis contraction ; Spastic pelvic floor syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Eighteen patients with chronic constipation were diagnosed as having paradoxical puborectalis contraction (PPC) as the cause for their constipation. The diagnosis of PPC was made after office evaluation, colonic transit study, manometry, cinedefecography, and electromyography (EMG). These 18 patients had a mean duration of symptoms of 26.9 years; none of these patients had unassisted bowel movements. Fourteen patients had a mean of 4.6 laxative-induced bowel evacuations per week, and 11 patients had a mean of 4.4 enema-induced bowel evacuations per week. Patients underwent a mean of 8.9 one-hour EMG-based biofeedback sessions. At a mean follow-up of 9.1 (range, 0.5–12) months, these 18 patients had a mean of 7.3 unassisted bowel actions per week ( P 〈0.0001). In addition, persistent laxative use was reported by only two patients, and, in both cases, this was once a week or less ( P 〈0.001). Similarly, enema use was reported by only three patients, one once weekly and the other two thrice weekly ( P 〈0.002). No biofeedback-related complications were identified. EMG-based biofeedback is a valuable technique associated with an 89 percent success rate in the treatment of PPC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1530-0358
    Keywords: Paradoxical puborectalis contraction ; Nonrelaxing puborectalis syndrome ; Anismus ; Constipation ; Defecography ; Electromyography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A prospective study was undertaken to assess the correlation between electromyography (EMG) and cinedefecography (CD) for the diagnosis of nonrelaxing puborectalis syndrome (NRPR). Clinical criteria for NRPR included straining, incomplete evacuation, tenesmus, and the need for enemas, suppositories, or digitation. EMG criteria included failure to achieve a significant decrease in electrical activity of the puborectalis (PR) during attempted evacuation. CD criteria included either paradoxical contraction or failure of relaxation of the PR along with incomplete evacuation. In addition, other etiologies for incomplete evacuation, such as rectoanal intussusception or nonemptying rectocele, were excluded by proctoscopy and defecography in all cases. One hundred twelve patients with constipation, 81 females and 31 males, with a mean age of 59 (range, 12–83) years were studied by routine office evaluation, CD, and EMG. Forty-two patients (37 percent) had evidence of NRPR on CD (rectal emptying: none, 24; incomplete, 18). Twenty-eight of these patients (67 percent) also had evidence of NRPR on EMG. EMG findings of NRPR were present in 12 of 70 patients (17 percent) with normal rectal emptying. Conversely, 14 of 72 patients (19 percent) with normal PR relaxation on EMG had an NRPR pattern on CD. The sensitivity and specificity for the EMG diagnosis of NRPR were 67 percent and 83 percent, and the positive and negative predictive values were 70 percent and 80 percent, respectively. Conversely, if EMG is considered as the ideal test for the diagnosis of NRPR, CD had a sensitivity of 70 percent, a specificity of 80 percent, and positive and negative predictive values of 66 percent and 82 percent, respectively. In summary, sensitivity, specificity, and predictive values of EMG and CD are suboptimal. Therefore, a combination of these two tests is suggested for the diagnosis of NRPR.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 34 (1991), S. 606-612 
    ISSN: 1530-0358
    Keywords: Electromyography ; Pudendal nerve ; Neurophysiology ; Anal sphincters ; Manometry ; Cinedefecography ; Anal physiology ; Constipation ; Fecal incontinence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract One hundred twenty consecutive patients with either fecal incontinence (60 patients), chronic constipation (41 patients), or idiopathic intractable pelvic pain (19 patients) were prospectively assessed. Patients underwent concentric needle electromyography (EMG), bilateral pudendal nerve terminal motor latency evaluation, anorectal manometry, and cinedefecography. The most common EMG finding in patients with fecal incontinence was decreased recruitment of motor units with squeezing and polyphasic motor unit potentials; these are consistent with an injury pattern. The most common EMG finding in the constipated patients was paradoxical puborectalis contraction. This latter abnormality was also a frequent finding in patients with rectal pain, as was prolongation of pudendal nerve latency. Paradoxical puborectalis contraction was diagnosed more frequently with EMG than with cinedefecography. Inter-examination correlation was best in the incontinent group between EMG and manometry. Cinedefecography had poor correlation with EMG in all patient groups but was valuable in the detection of additional pathology such as rectoanal intussusception and anterior rectocele. Electromyography including pudendal nerve terminal motor latency assessment is a valuable adjunct in the evaluation of disorders of evacuation. The information it yields is complementary to that offered by more routine physiologic examinations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1530-0358
    Keywords: Defecography ; Proctography ; Balloon sphincterography ; Anorectal angle ; Constipation ; Fecal incontinence
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A prospective study was undertaken to compare two different methods of measuring the anorectal angle (ABA), balloon proctography (BP) and cinedefecography (CD), as well as to evaluate the reproducibility of this measurement using each technique. One hundred four consecutive patients (75 women and 29 men) with constipation (63 patients), fecal incontinence (25 patients), or rectal pain (16 patients) underwent both BP and CD. The ARA was measured by taking lateral radiographs of the pelvis during rest (R), squeeze (S), and push (P). The same interpretation process was performed 2 to 12 months later by the same observer, blinded as to diagnosis and initial measurements. There were highly significant differences in each measurement category, R ( P 〈 0.0001), S ( P 〈 0.0001), and P ( P 〈 0.0004 between BP and CD. However, the correlation between the first and second measurements was excellent ( P 〈 0.0001). BP was consistently more difficult to interpret because of balloon configuration. Although BP and CD have poor correlation with each other, each examination can be reliably interpreted. CD appears to be a superior examination because of the added ability to delineate rectoceles, intussusceptions, and other structural defects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 34 (1991), S. 851-856 
    ISSN: 1530-0358
    Keywords: Constipation ; Colonic inertia ; Colectomy ; Colonic dysmotility ; Slow transit constipation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The results of total abdominal colectomy (TAC) with ileorectal anastomosis as a treatment for colonic inertia (CI) were prospectively assessed. One hundred sixtythree patients were evaluated for chronic constipation between July 1988 and November 1990. Patients underwent pancolonic transit times, anorectal manometry, cinedefecography (CD), and electromyography (EMG). CI was defined as diffuse marker delay on transit study without evidence of puborectalis contraction on CD or EMG. Sixteen patients (10 percent; 15 females and 1 male) with a mean age of 45 years (range, 24–75 years) with CI underwent TAC. Preoperative bowel frequency ranged from three per week to one per month; all 16 patients evacuated only with high doses of laxatives, enemas, or both. TAC was performed with no postoperative mortality or major morbidity; three patients were readmitted four times for successful conservative treatment of partial small bowel obstruction. At a mean followup of 15 months (range, 2–35 months), these 16 patients reported a mean frequency of spontaneous bowel evacuations of 3.5 per day (range, one to six per day). Patient satisfaction with the operation was “excellent” or “good” in 15 cases (94 percent). Thorough preoperative physiologic evaluation permits the selection of a small group of patients with CI who may benefit tremendously from TAC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 603-607 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fractional dietary Ca absorption, ‘a’, is measured by determining the ratio of two stable isotopic tracers, one of them orally (44Ca @ 0.2-0.5 mg/kg) and the other intravenously (42Ca @ 0.02-0.1 mg/kg). Thermal ionization mass spectrometry (TIMS) is used to measure the perturbation of natural abundance isotope ratios (delta % excess). Typical sensitivity of the TIMS permits detection of a 2.5 delta % excess change from the natural Ca isotope ratio with relative standard deviations of about 0.5%. At sufficiently long times absorption becomes constant so that ‘a’ is determined by a product of constants and a measured ratio.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 876-880 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The electron ionization mass spectra of fourteen 4-substituted (4-X) camphors have been recorded and analyzed using metastable ion analysis and exact mass measurement. With respect to camphor, alkyl substituents changed the relative importance of different fragmentation pathways, though they did not induce new fragmentations. Substituents X connected to the camphor framework through an atom having a lone pair of electrons were generally lost as HX. Overall the fragmentation behaviour was essentially independent of the inductive substituent constant. Under chemical ionization conditions, only methane of the reagent gases produced extensive fragmentations of these compounds; isobutane, acetone and ammonia were ineffective. The nature of the fragmentations was independent of both the inductive substituent constant of the substituent X and the proton affinity and heat of formation of the corresponding neutral compound HX.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1040-7685
    Keywords: chiral ; separation ; micellar ; capillary ; electrophoresis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This article describes the synthesis of a novel chiral surfactant based on (R,R)-tartaric acid. (R,R)-Tartaric acid is acetylated while simultaneously forming a cyclic anhydride, which is then reacted with n-decylamine forming a chiral, long chain carboxylic acid. This carboxylic acid is then further reacted with the achiral amino acid taurine forming the required surfactant which has a sulfonic acid headgroup. Evidence for its surface activity and an estimate of its critical micelle concentration (cmc) have been obtained using surface tension measurements and conductivity. The surfactant has then been used as the additive in micellar electrokinetic capillary chromatography (MECC) to achieve chiral separations of compounds with multiple aromatic functionality. These separations are compared with those achieved with previously reported tartaric acid based surfactants which show a difference in selectivity. © 1995 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 22 (1993), S. 181-183 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In 10 mM sodium phosphate, pH 7.6, containing 0.1 mM ethylenediaminetetraacetic acid, ions corresponding to the non-covalent, four-stranded oligonucleotide, d(CGCG4GCG)4, were detected by negative ion electrospray ionization (ESI) mass spectrometry at a low nozzle-skimmer (ΔNS) bias (-150 V), but not at a higher ΔNS bias (〉 -250 V). In contrast, when the sample was desalted and analyzed by ESI mass spectrometry at a low ΔNS bias only ions for the single-stranded d(CGCG4GCG) species were observed. These data agree with spectroscopic evidence which showed that oligonucleotides with the sequence motif 5′d(CGCGnGCG)3′, where n = 2-5, formed stable four-stranded complexes in the presence of monatomic cations, like K+, Ca2+, Na+ and Li+, but not in their absence.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 25 (1985), S. 896-902 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Mixtures of 90, 80, and 70 percent by weight bisphenol-A-polycarbonate (PC) and 10, 20, and 30 percent by weight styrene maleic anhydride (SMA) copolymer were melt-blended in a single screw extruder. Differential scanning calorimetry (DCS) and scanning electron microscopy (SEM) were used to determine the miscibility of the blends. The viscosity, as a function of shear rate and temperature, was measured by an Instron capillary viscometer. The notched impact strength as a function of temperature was measured by an Izod impact tester.The results of DSC showed two glass transition temperatures which merged slightly towards each other, indicating marginal miscibility of these blends. There was a decrease in viscosity as the fraction of SMA copolymer was increased. The most significant decrease occurred with the initial addition of SMA copolymer. The viscosity also decreased with increases in temperature. The impact strength of the blends was also dependent on SMA copolymer content. The blends showed six to ten times lower impact strengths at room temperature than the 100 percent polycarbonate. SEM analysis helped to determine the reason why the impact strength was lower for the blends. High magnification showed the presence of SMA copolymer inclusions dispersed throughout the PC matrix. These inclusions, which increased in size as SMA copolymer content was increased, acted as defects in the system.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...