Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (2)
  • Hepatocytes  (1)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 6 (1992), S. 224-226 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Haemoglobin obtained from a male adult Ghanian with retinopathy, which was probably caused by haemoglobinopathy was analysed by capillary electrophoresis (CE) for clinical diagnosis. Two major peaks, which were in the ratio of nearly one, were detected. The elution times of these peaks (HbXI and HbXII) were faster than that of normal haemoglobin (HbA). The existence of two different abnormal types of haemoglobin was clear in the patient blood. The following sequence analysis revealed that the first peak (HbXI) was HbC and the second (HbXII) was HbS on the electropherogram, and that the patient was a heterozygote of HbS and HbC (HbSC disease). One of the diagnostic processes in a haemoglobin disease was shown by the combined use of CE, HPLC and a protein sequencer.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 162-165 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A high performance liquid chromatographic (HPLC) procedure for measuring pyridoxal-5′-phosphate (PLP) and certain forms of B6 vitamers in plasma is presented here. This HPLC procedure consisted of a single graphitic carbon column with a fluorescence detector employing an isocratic eluent (15% acetonitrile:1% perchloric acid: 0.05% sodium bisulfite). The graphitic carbon column is useful in acidic eluent without deteriorization. The relatively low fluorescent intensity of PLP under acidic conditions is improved by its derivatization with bisulfite in the eluent during chromatographic separation. Using this procedure, the detection limit of PLP is 50 fmol, and an aliquot of 5-50 μL of human plasma is required giving satisfactorily precise results within 5 min. We applied this method to the determination of PLP and certain B6 vitamers in human plasma after oral supplementation of pyridoxine.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    The @Anatomical Record 241 (1995), S. 149-154 
    ISSN: 0003-276X
    Keywords: Mitochondria ; Helical filaments ; Hepatocytes ; Ethanol ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Background: Packets of helical filaments have been observed in the outer compartment of occasional mitochondria in many cell types in a variety of animals. The compositon and funcation of these intramitochondrial helical filaments (IMHF) are unknown.Methods: IMHF wre induced in a hepatic mitochondria by administration of ethanol in the drinking water of rats. Hepatic mitochondria were isolated and ruptured by osmotic shock, relasing their IMHF. To purify these structures, the IMHF-containing supernatant was further fractionated by ammonium sulfate precipitation, a 50-60% solution of this reagent being the most effective in this regard. Isolated IMHF were examined by electron microcopy and were analyzed by SDS-PAGE.Result Isolated IMHF closely resembled their in situ counterparts: they had a right-handed helical structure with a 16 nm pitch. SDS-PAGE analysis revealed that they contained three polypeptides with weigh tmolecular of 135, 98, and 53 kD, respectively.Conculusions: These observations will stand as a aseline for comparisons with IMHF that occur naturally or that are induced in other cell types by other kinds of experimental manipulation. © 1995 Wiley-Liss, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...