Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 103-106 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Plasma ; Verapamil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A specific, sensitive, and accurate assay for quantitation of verapamil has been developed. The method involves a single extraction step with n-heptane, followed by evaporation at room temperature under nitrogen. 0.1 μl of the extract was injected into a capillary column coated with crosslinked 5% phenylmethylsilicone. The column separated verapamil, norverapamil, and its internal standard within 15 minutes using temperature programming from 90 to 290°C. The lower limit of detection was 1 ng/ml for verapamil. The calibration curve was linear in the concentration range (5-300 ng/ml). Plasma concentration data from dogs receiving intravenous verapamil infusion are presented.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...