ISSN:
1612-1112
Keywords:
Gas chromatography
;
Electron capture detector
;
Anti-picornaviral agent in dog serum
;
Enteroviruses
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
Notes:
Summary A gas chromatographic assay for the determination of SCH 48973, a potent broad spectrum anti-picornaviral agent, was developed and validated in dog serum. The method involved extraction with organic solvent followed by separation on a capillary column (DB-1) with quantitation by an electron-capture detector. The method was sensitive with a limit of quantitation of 10 ng mL−1. The linearity of the method was satisfactory as indicated by correlation coefficients of 〉0.999 and visual examination of the calibration curves. The method was precise with a coefficient of variation ranging from 2.3 to 13.2% and accurate with a bias ranging from −9.1 to 7.9%. Moreover, SCH 48973 was stable in dog serum after being subjected to three freeze-thaw cycles. The assay was shown to be sensitive, specific, accurate and precise, and reliable for use in pharmacokinetic or toxicokinetic studies.