Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Key words: Virtual images ; Helical CT ; Image processing ; Aorta ; Grafts and prostheses ; Rupture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. We describe a case of graft-related pseudoaneurysm of the abdominal aorta evaluated with spiral CT and DSA. Spiral CT data sets were processed to obtain surface-rendered internal views (virtual angioscopy, VA) of the graft and the pseudoaneurysm, and to demonstrate from inside the lumen the site of dehiscence. A jet flow phenomenon inside the pseudoaneurysm was observed at DSA. Spiral-CT axial images, multiplanar volume reconstructions with maximum intensity projections, and shaded surface display showed the site of rupture. The VA findings were: (a) from inside the graft lumen, the evidence of a communication canal between the graft and the pseudoaneurysm; and (b) from inside the pseudoaneurysm, the presence of a jet flow. The VA findings showed good correlation with those obtained with the other imaging techniques.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 8 (1998), S. 679-684 
    ISSN: 1432-1084
    Keywords: Key words: CT angiography ; Aorta ; CT 3D reconstructions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Since the introduction of helical scanners, CT angiography (CTA) has achieved an essential role in many vascular applications that were previously managed with conventional angiography. The performance of CTA is based on the accurate selection of collimation width, pitch, reconstruction spacing and scan delay, which must be modulated on the basis of the clinical issue. However, the major improvement of CT has been provided by the recent implementation of many post-processing techniques, such as multiplanar reformatting, shaded surface display, maximum intensity projections, 3D perspectives of surface and volume rendering, which simulate virtual intravascular endoscopy. The integration of the potentialities of the scanner and of the image processing techniques permitted improvement of: (a) the evaluation of aneurysms, dissection and vascular anomalies involving the thoracic aorta; (b) carotid artery stenosis; (c) aneurysms of abdominal aorta; (d) renal artery stenosis; (e) follow-up of renal artery stenting; and (f) acute or chronic pulmonary embolism. Our experience has shown that the assessment of arterial pathologies with CTA requires the integration of 3D post-processing techniques in most applications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...