Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid Chromatography ; Chemiluminescence detection ; Solid reagent bed ; Quinone detection
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The combination of solid-state peroxyoxalate chemiluminescence detection and post-column chemical reaction systems in liquid chromatography is investigated. Bis-2,4,6-trichlorophenyloxalate (TCPO) is added from a solid reagent bed with the fluorophore, 3-aminofluoranthene, immobilized on glass beads. Hydrogen peroxide generated photochemically by quinone analytes is measured. Flow splitting is shown to be a simple means of reagent addition with a negligible band broadening effect. This system is compared to a more flexible dualpump design. To minimize band broadening in both systems, the reagent bed is located out of the path of the chromatographic effluent. Detection limits are in the sub-picomole range, an imporvement relative to those previously reported with TCPO added in the liquid phase. These systems can be easily be adapted for detection of peroxide generated by other post-column reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 11-14 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Fluorescence ; Ion-pair extraction ; Amines ; Post-column reaction ; Auto-analyser ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detection system is described which is based on fluorescent ion-pair formation between tertiary amine drugs and dimethoxyanthracene sulphonate. A dynamic micro-extraction principle is then used to isolate the ion-pairs from the excess reagent. The band broadening of this extraction detector was kept below 20% using standard auto-analyser equipment. With the enhanced selectivity and sensitivity of this approach it was possible to analyse chloropheniramine in urine at ppb concentrations using a pre-column clean-up trace enrichment step.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...