    International archives of occupational and environmental health 65 (1993), S. S7 
    ISSN: 1432-1246
    Keywords: DNA-adduct ; Effect-markert ; Exposure-markert ; Protein-adductt ; Sensitivity-marker
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Biologic markers are familiar tools for monitoring human absorption of, and reaction to, potentially toxic chemicals. The concept of applying biologic markers to the risk assessment process is a natural, but more recent, development and the principles remain to be fully elaborated. Biologic markers may be measurements of exposure, of effects, of genetic or induced sensitivity or of disease. The ideal biologic marker for risk assessment purposes is a quantitative measurement of a chemical, biochemical, functional or morphological change in the system that is initiated by a chemical and which results in pathologic change and overt toxicity. It follows that some understanding of the mechanism of toxicity and of dose-response relationships are pre-requisite for selection of suitable biologic markers for use in risk assessment. Where biologic markers for toxicity are common between mammalian species, extrapolation of data for quantitative risk assessment purposes becomes more reasonable. In the field of carcinogenesis, some DNA and protein adducts have been proposed as biologic markers for assessment of risk associated with exposure to genotoxic carcinogens. However, less progress is evident in relation to other toxic end-points including those for pulmonary, reproductive, immuno- and neuro-toxicity, despite intensive efforts.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 216-220 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, at 25O°C ; Sampling via precolumn enrichment ; Precolumn backflush, reinjection after trapping the volatiles ; Rejection of non-volatiles ; Automation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel sampling system for isothermal capillary gas chromatography of medium- or low-volatility mixtures is described and test results are reported using flame ionization detection. The system features a loading and positioning chamber for glass vials which can carry a dilute sample in up to 0.2 ml of a volatile solvent. The output from the glass vaporization chamber is trapped onto a packed precolumn operated in the backflush mode. The analytes are further transferred over a wall-coated capillary trap prior to isothermal capillary GLC. Repeat-cycle operation of the sampling system requires 10 channels of a processor for time control over 5 solenoid valves and 3 static heaters. Preliminary results with long-chain n-alkanes in the submicrogram range showed no unwanted effects. The principal claim of the system is an improved rejection of non-volatiles.