Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1279-8517
    Keywords: Mandible ; Holographic interferometry ; Static stresses ; Tri-dimensional composites ; Transversal isotropy and anisotropy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Afin de tenter de déterminer la nature de la structure mécanique de la mandibule, les auteurs ont respectivement comparé, à l'aide de l'interférométrie holographique, le comportement de mandibules fraîches de cadavre, celui d'une équerre métallique représentative et celui d'un bloc de carbone-carbone 3D sous contraintes statiques. Il n'existe aucune similitude entre le comportement de la mandibule humaine et celui d'un acier polycristallin. A l'inverse, celui de la mandibule et celui du carbone-carbone 3D sont très voisins. Il serait prématuré d'affirmer que le matériau osseux est un composite hétérogène. Tout au plus peut-on démontrer, ce qui est une première approche, qu'il a un comportement très voisin, dans des conditions d'expériences identiques et pour des contraintes identiques. Les auteurs ont également démontré que la mandibule présentait un phénomène d'hystérésis mécanique, c'està-dire que soumise à une contrainte très faible, elle se déforme mais que cette déformation ne tend à s'annuler que partiellement et dans le temps.
    Notes: Summary In order to try to determine the nature of the mechanical structure of the mandible, the authors have compared, with the help of holographic interferometry, the behavior of the fresh mandible of a corpse, of a representative iron angle, and of a block of carbon-carbon under static constraint. There are no similarities between the behavior of the human mandible and that of a polycrystalline steel. On the contrary, the behavior of the mandible and of the carbon-carbon block are very similar. It would be hasty to state that bones are a heterogenous composite. We can only prove, in a first approach, that they behave similarly under identical experimental conditions. The authors also demonstrated that the mandible presents a “mechanical hysteresis” phenomenon. This means that, when subjected to a small strain, its shape changes, but this change tends to neutralize itself in part in the course of time.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1279-8517
    Keywords: Mandible ; Constraints ; Deformations ; Isotropy ; Anisotropy ; Mechanical fusibles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé A l'aide de la méthode des éléments finis et d'un ≪ modèle modifié ≫, les auteurs ont étudié les déformations d'une mandibule isolée de son contexte musculaire et soumise à des contraintes statiques. Ont été successivement calculés: la déformation générale de la mandibule et ses modifications en fonction de la direction d'application de la charge, les phénomènes de rotation ou de ≪ vrillage ≫ de coupes de mandibules isolées par l'ordinateur, les déformations respectives des corticales interne et externe. Il a été mis en évidence des phénomènes mécaniques singuliers correspondant aux zones où siègent les formes anatomo-cliniques des fractures mandibulaires. Les auteurs en concluent que la mandibule a le comportement mécanique d'un matériau composite 3D très hétérogène.
    Notes: Summary The authors have studied the deformations of a mandible isolated from its muscular environment and submitted to statical constraints, with the help of a “modified model” and the finite elements method: the general deformation of the mandible and its modifications according to the direction of the application of the pressure, the rotation phenomenon or “torsion” in cross sections (identified by computer) of the mandible, the respective deformations of the internal and external corticals have successively been calculated. Particular mechanical phenomenons corresponding to the areas where the anatomo-clinical forms of the mandibulary fractures take place have clearly been shown. The authors draw the conclusion that the mandible behaves mechanically in a similar way to a tridimentionnal composite.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 10 (1988), S. 29-36 
    ISSN: 1279-8517
    Keywords: Calvarium ; Biomechanics ; Arches and strengthening pillars ; Sandwich structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Les auteurs se demandent s'il existe réellement des poutres et des travées de renforcement au niveau de la calvaria, quelle est, dans l'affirmative, leur correspondance anatomique exacte ainsi que leur rôle exact dans l'inertie de la calvaria. Ils estiment que ce rôle est secondaire hormis pour les piliers frontal et occipital interne. Pour eux, l'inertie de la calvaria doit être attribuée à sa « structure sandwich » avec, cependant, des renforts locaux là où il existe des sur-contraintes. S'ils croient bien à l'existence de certains renforts calvaria-chassis endochondral basicrânien, tels les piliers occipitaux, ils dénient toute réalité anatomique et mécanique au concept des piliers mastoïdiens, le processus mastoïdien étant une structure à « peau » mince et à remplissage aréolaire, dont l'avantage est de donner au m. sterno-cléido mastoïdien et au m. digastrique la plus grande aire d'insertion sur une structure légère.
    Notes: Summary The authors question whether strengthening beams and spans for the calvarium really exist and, if so, what are their exact anatomic counterparts and their exact function in the resistance of the calvarium. They opine that this function is of secondary importance except for the frontal and internal occipital pillars. The resistance of the calvarium must rather be attributed to its sandwich structure, with local bracing where the constraints are too severe. While they believe in the existence of such braces as the occipital pillars between the calvarium and the endochondral skull base, they prefer the concept of the mastoid pillars. The mastoid process is a structure with a thin shell and alveolar content, which has the advantage of giving the sternocleidomastoid and digastric muscles a bigger area of attachment to a light structure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗