Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1433-2965
    Keywords: Bone ; Bone fluoride content ; Calcification defects ; Osteoporosis ; Sodium fluoride treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Fluoride treatment is used to increase bone formation and cancellous bone mass in patients suffering from postmenopausal osteoporosis with vertebral fractures. Patients submitted to similar therapeutic protocols have shown various histological responses to the treatment, some developing calcification defects and others not. In fact, the bone histological response to fluoride salts depends on the cumulative uptake of fluoride by bone. To clarify the relationship between the presence of calcification defects (identified by the presence of mottled bone and linear formation defects) and the bone fluoride content, a retrospective study was performed on 29 women with type 1 osteoporosis and treated for several months (11–24) with sodium fluoride (50 mg/day), calcium and vitamin D. Bone fluoride content always significantly increased after treatment, but it was significantly higher in patients showing calcification defects than in those having no defects. These differences between the two groups of patients were not due to differences in clinical details (no significant differences concerning age, duration of treatment, total amount of fluoride ingested, renal function) or in their bone remodelling activity. Thus, it may be hypothesized that the high bone fluoride uptake is due to different individual responses from one patient to another concerning the bioavailability of the same dose of fluoride. This is difficult to predict, except by testing the individual bioavailability of the compound to be used in each patient before starting long-term treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Bone fluoride content ; Bone remodeling ; Fluoride ; Histomorphometry ; Lambs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The evolution of bone changes induced by fluoride after the end of exposure was investigated in lambs. Sodium fluoride (NaF) was given orally at a dose of 3.5 mg/kg per day to 14 animals for 120 days. A group of 7 control and 7 treated lambs was slaughtered at the end of NaF administration (T120) and another group 120 days after the end of NaF exposure (T240). At T120, the bone fluoride content (BFC) was very significantly increased in treated animals. The histomorphometric analysis confirmed that fluoride induces an increase in bone formation (the osteoid perimeter and area were 3-fold and 4.5-fold higher respectively in treated than in control animals). The number of osteoblasts was significantly augmented. Serum osteocalcin level was twice as high in treated animals compared with controls. The bone formation rate at the tissue level (BFR) doubled after treatment, but the apposition rate (Aj.AR) was half that in the control group. The mineralization lag time (Mlt) was 120 days in treated animals compared with 42 days in controls. At T240, BFC had decreased by 50% compared with the level at T120, but it was still significantly higher than in controls. The osteoid and osteoblastic parameters were 2 and 1.3 times higher than in control animals. BFR remained significantly increased in treated animals, but Aj.AR and Mlt were similar in control and treated animals. In conclusion, after 4 months of NaF exposure fluoride induced an increase in osteoblast natality and bone formation at the tissue level, associated with a toxic effect at the individual cell level. Four months after the end of NaF exposure, positive effects on bone formation were still present but the evidence of cellular toxicity had disappeared.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-2965
    Keywords: Calcium ; Cardiac transplantation ; Fluoride ; Glucocorticoid-induced osteoporosis ; Parathyroid hormone ; Vitamin D
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Of 203 patients who underwent cardiac transplantation and were given long-term treatment with cyclosporine and 0.3 mg/kg per day prednisone, 123 were studied prospectively for at least 6 months and 46 for up to 2 years to evaluate the effects on lumbar bone mineral density (BMD) and calcium metabolism of a combined therapy with calcium, calcidiol and disodium monofluorophosphate (MFP). The population was arbitrarily assigned to one of two groups. Group I consisted of patients who had a lumbar spine BMDZ score above −1.5 SD as compared with an age-and sex-matched population and no vertebral fractures. They received daily 1 g elemental calcium and 25 µg (1000 IU) calcidiol. Group II consisted of patients who received daily the same doses of calcium and calcidiol combined with 200 mg MFP, and was divided into two subgroups: (a) osteopenic subjects who had a lumbar spine BMD Z score below −1.5 SD without vertebral fractures and (b) osteoporotic subjects with vertebral fractures. If serum creatinine was higher than 140 µmol/l the daily dose of MFP was tapered to 100 mg. Fifty-four and 27 patients from group I and 38 and 19 patients from group II were followed respectively for 12 and 24 months. In both groups serum parathyroid hormone levels were significantly reduced from the twelfth month in parallel with a significant increase in serum 25-OHD levels. No decline in lumbar BMD occurred in non-osteopenic and non-osteoporotic patients (group I) who received the calcium and calcidiol supplement. In group II, where MFP was added, a significant and linear increase in lumbar BMD was observed. The average increase reached 12.5% after 12 months and 29.5% after 24 months (p〈0.0001). The magnitude of the response was similar to the response previously reported in patients suffering from vertebral fractures due to postmenopausal osteoporosis and treated with the same daily dose of MFP. Because osteoporosis and fractures are not rare in patients after cardiac transplantation, these pilot results may be useful for further prevention and treatment trials of bone loss in this condition.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1433-2965
    Keywords: Aging ; Bone loss ; Bone mineral density ; Broadband ultrasound attenuation ; Speed of sound ; Stiffness index ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We performed repeated ultrasound measurements approximately 2 years apart (average 23 months ±3 months) on the os calcis of 113 healthy postmeno-pausal women recruited from two large prospective cohort studies named OFELY and EPIDOS. Group A (from OFELY) consisted of 88 women aged 52–72 (63±5) years, randomly selected from a large insurance company, and group B (from EPIDOS) consisted of 25 women aged 75–88 (80±4) years, randomly selected from the voting lists. We obtained broadband ultrasonic attenuation (BUA) and speed of sound (SOS) measurements, as well as the Stiffness index, with a Lunar Achilles ultrasound machine. We performed dual energy X-ray absorptiometry (DXA) measurements of femoral neck bone mineral density (neck BMD) with a Hologic QDR 2000 for group A and with a Lunar DPX Plus for group B. The decrease that we observed over 2 years was on average ±1 SD: −1.01±4.6 dB/MHz (p=0.02) for BUA (which is approximately equal to the long-term precision error in vitro), −11.3±9.2 m/s (p=0.0001) for SOS (approximately 5 times the precision error), −3.8±4.2 %YA (p=0.0001) for Stiffness (2.5 times the precision error) and −0.01±0.03 g/cm2 (p=0.0001) for neck BMD (approximately equal to the precision error). In terms of percentage change this represents: −1.0%±4.3% for BUA, −0.8%±0.6% for SOS and −1.85%±4.4% for neck BMD. At the individual level, most SOS and Stiffness values were consistent with a decrease, whereas BUA and neck BMD values were spread out above and below the zero line of no change. The decreases in SOS and Stiffness were significantly larger in the early postmenopause (⩽20 years since menopause [YSM]) than in the late postmenopause (〉20 YSM). We observed a similar trend for BUA and BMD but this did not reach statistical significance. We found a weak but significant correlation between changes in ultrasound variables and changes in neck BMD. However, the 2-year changes observed in SOS were not significantly correlated with changes in BUA. This study suggests that the heel ultrasound measurements of SOS and Stiffness are valuable indices of postmenopausal bone loss, and could be used for follow-up in therapeutic trials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1433-2965
    Keywords: Bone ; Histomorphometry ; Osteoporosis ; Osteoblasts ; Osteocalcin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To assess the bone turnover abnormalities which characterize postmenopausal osteoporosis with vertebral fractures (PMOp), a transiliac bone biopsy was performed after double labeling of the mineralizing front with tetracycline in 50 untreated PMOp patients who were compared with 13 healthy age-matched volunteer females. The analysis of bone remodeling and structure parameters demonstrated that PMOp is a disease affecting both the cancellous and the endocortical envelopes and characterized by increased resorption and by a marked decrease in the osteoblastic apposition rate due to a reduced duration of bone formation. This induces a decrease in the width of both individual osteons and trabeculae. In PMOp, the wide spectrum of bone turnover as compared with the controls, associated with the typical bimodal distribution of cancellous osteoid perimeter, allowed us to identify two subsets, one with normal turnover (NT) and one with high turnover (HT) representing 30% of the cases. When compared to NT, HT was characterized by increased osteoclast number, lower bone volume, thinner osteons, increased formation at the tissue-level and markedly decreased duration of formation. In HT the marked decrease in the duration of activity of osteoblasts and the markedly increased number of osteoclasts induced a greater decrease in bone volume, despite the increase of bone formation at the tissue level. These subsets could not be distinguished by any clinical or biochemical parameter except for serum bone gla protein (osteocalcin) which was significantly higher (as a group) in HT than in NT. The underlying cause for these two subsets is unknown. We conclude that PMOp affects the cancellous and the endocortical bone. Bone loss results from a wide spectrum of bone turnover abnormalities, with two distinct subsets, one with normal turnover and one with high turnover.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0827
    Keywords: Broadband ultrasound attenuation ; Speed-of-sound ; Stiffness index ; Interunit precision
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract Ultrasonic assessment is a new approach to assess both quality and density. Two ultrasonic parameters are measured on the os calcis: the attenuation or broadband ultrasound attenuation (BUA) and the velocity or speed of sound (SOS). The interunit variations in vitro and in vivo of an ultrasound instrument, the Lunar AchillesR system, used in a French multicenter study named EPIDOS, were calculated and the stability of these intruments over a 12-month period was evaluated. A third parameter called “stiffness index”, calculated from the SOS and BUA, was also used in this study. The average CV in vitro for the BUA and SOS was 0.92% and 0.12%, respectively, and the average CV in vivo for the BUA, the SOS, and the stiffness index was 1.83%, 0.23%, and 1.9%, respectively. The interunit (or inter-machines) variations were calculated by a one-way analysis of variance. We detected small but significant measurement differences among centers on a phantom for both SOS (maximum significant difference 0.4%) and stiffness (maximum significant difference 3.5%) but not for BUA. Similar diffrences were found in vivo. The precision over 12 months of the interunit variations in vitro was evaluated by measuring a single phantom traveling from one center to another several times. The range of the CV for the BUA (1.54–0.51%), for the SOS (0.25–0.14%), and for the stiffness index (2.26–1.10%) are explained in part by technical failures. The variation among the five Achilles was estimated by the combined CV which was 1.42% for the BUA, 0.32% for the SOS, and 2.33% for the stiffness index. In conclusion, our findings indicate that equipment from one manufacturer appears to be consistent between machines for the BUA, but not completely for the SOS. The results for this stiffness index are necessarily influenced by both SOS and BUA. The shortterm and long-term interunit precision is good, both in vitro and in vivo. Such results provide increased confidence in multicenter clinical trials where ultrasonic data are pooled.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...