    Springer
    Osteoporosis international 6 (1996), S. 207-212 
    ISSN: 1433-2965
    Keywords: Accuracy ; Ash weight ; Bone mineral measurement ; Peripheral quantitative computed tomography (pQCT) ; Precision ; Radius
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We evaluated the accuracy and precision of a peripheral quantitative computed tomography (pQCT) scanner, the Stratec XCT-960, using 12 human cadaveric forearms. The accuracy was determined by comparing the total bone mineral content (BMC) with the ash weight (AW). We scanned and ashed three consecutive slices (thickness 2.5 mm) at the standard position (s-position) and at 2.5 mm both proximal and distal to the s-position. The correlation coefficient between the AW and total BMC using slices at the s-position wasr=0.87 with an accuracy error (random component) of 15.5%. The correlation coefficient using all slices wasr=0.90 with an accuracy error of 14.3%. The correlation coefficient improved tor=0.95 with an accuracy error of 9.7% after averaging the results of all three slices for each forearm. The short-term precision error expressed as the coefficient of variation (CV) of bone mineral density (BMD) and BMC was determined by measuring the forearms five times either with repositioning or without repositioning. The CVs with repositioning were 2.77 and 1.15 for total BMD and BMC, 1.85 for trabecular BMD; without repositioning they were 0.29, 0.58 and 0.69 respectively. To further evaluate the influence of positioning, additional scans were performed at 1, 2 and 5 mm proximal, and 1 and 2 mm distal to the s-position. BMD and BMC were greatly influenced by the scan location; for example, the percentage differences in trabecular BMD 1 mm distal and proximal relative to the s-position were 2.5%±5.1% and 0.18%±6.3%, respectively. The Stratec XCT-960 appears to be a moderately accurate and highly precise scanner with potential usefulness for evaluating BMC and BMD of ultradistal radius.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...